Andrew Gabor | BrightSpot Automation LLC: How do you separately image both junctions of a tandem cell with one photoluminescence tool?
05:28 - 06:39
Other snippets from this talk
Summary of the clip:
How do you separately image both junctions of a tandem cell with one photoluminescence tool?
Different shunt types can be inferred differently across coloured boxes. For tracking band gap variations, a filter wheel mounts in front of the camera. Different filter band pass stacks probe the centre, left and right portions of an emission peak. Simple math then yields a figure of merit for band gap drift, or variation, for example a simple ratio.
For tandem structures, solutions exist for both electroluminescence and photoluminescence. In EL, the filter wheel serves both junctions: one position captures the left emission peak for the top junction, then the wheel switches to the next position for the bottom junction peak. One tool images each junction in sequence.
Photoluminescence needs a different excitation scheme. A blue LED excites the top junction. For the bottom junction, a near-infrared series of LEDs is used; that light passes through the top junction and is absorbed in the bottom cell. Two different filter wheel locations then separate the signals.
In this short video, you can learn:
* A filter wheel in front of the camera probes different band pass stacks across an emission peak.
* For tandem electroluminescence, one filter position reads the top junction peak and another reads the bottom junction peak.
* For tandem photoluminescence, a blue LED excites the top junction while near-infrared LEDs pass through it to excite the bottom cell.
π **Clip Abstract** Tandem cells need separate imaging of both junctions. A filter wheel plus blue and near-infrared excitation lets one photoluminescence or electroluminescence tool probe top and bottom peaks, and simple ratios turn band gap drift into a figure of merit.
About the speaker:
* Speaker: Andrew Gabor
* Company: BrightSpot Automation LLC
* Event: nnovation Festival: Additive, Printed, Sustainable Electronics, MicroLEDs and AR/VR Displays, Perovskites | July 2026
* Location: Online Platform
Annual access to our onsite event(s), all online events and a library featuring over 1800 presentations (recordings + PDF) across all our onsite and onsite events and technology areas. Join us and over 2000 members from around the world now.
Explore and join now --> https://www.techblick.com/
#FilterWheel, #BandGapDrift, #NearInfraredExcitation, #TandemJunctionImaging, #PerovskiteSolar, #SolarMetrology
This is a highlight of the presentation:
Photoluminescence Imaging for In-Line Metrology in Perovskite and Tandem Solar Panel Manufacturing
More Highlights from the same talk.
07:30 - 09:38
How can PL imaging extract IV curves, ideality factors and efficiency maps without contacting the cell?
How can PL imaging extract IV curves, ideality factors and efficiency maps without contacting the cell?
With electroluminescence capability, dark IV comes for free by scanning the IV curve. Recently added functionality shifts that curve downward by a typical short-circuit current value, then extracts figure-of-merit values for the IV parameter. Adding a simple electronic load unit gives free light IV scanning using PL light sources; the spectrum is not accurate, but it is quite repeatable.
Then compare curves containing all loss factors with two other curves: the pseudo IV or Sun's Voc curve, which excludes series-resistance effects, and the implied Voc curve generated from the sequence of PL images taken at each intensity, removing all contact effects. Taking that series of PL images at different intensities also extracts a figure-of-merit plot called the optical ideality factor.
With additional math, three other implied figure-of-merit plots can be extracted: implied open-circuit voltage, fill factor and conversion efficiency. Adding the electronic load allows two additional images near the maximum power point and further math to provide maps of J0, series resistance and conversion efficiency. These tools are factory ready, providing factory automation.
In this short video, you can learn:
* Adding a simple electronic load unit enables free light IV scanning with PL light sources, though the spectrum is not accurate it is repeatable.
* Comparing loss-containing curves with pseudo IV or Sun's Voc and implied Voc curves separates series-resistance and contact effects.
* A series of PL images at different intensities yields optical ideality factor, plus implied open-circuit voltage, fill factor and conversion efficiency, with J0 and series-resistance maps near maximum power point.
π **Clip Abstract** Non-contact PL imaging can scan dark IV curves and, by shifting downward by a typical short-circuit current, extract IV figure-of-merit values. Adding an electronic load gives repeatable light IV scans across intensities, enabling pseudo IV, Sun's Voc, implied Voc, optical ideality factor, J0, series-resistance and efficiency maps, with factory-ready automation.
About the speaker:
* Speaker: Andrew Gabor
* Company: BrightSpot Automation LLC
* Event: nnovation Festival: Additive, Printed, Sustainable Electronics, MicroLEDs and AR/VR Displays, Perovskites | July 2026
* Location: Online Platform
Annual access to our onsite event(s), all online events and a library featuring over 1800 presentations (recordings + PDF) across all our onsite and onsite events and technology areas. Join us and over 2000 members from around the world now.