top of page

Behzad Shirmardi

BrightComSol GmbH

* All members of the platform can watch the entire presentation.

 

Please register to become a member.

Behzad Shirmardi | BrightComSol GmbH: Does a 7 ns perovskite QD scintillator beat thallium-doped CsI for real-time X-ray imaging?

08:09 - 09:34

Other snippets from this talk

Summary of the clip:

Does a 7 ns perovskite QD scintillator beat thallium-doped CsI for real-time X-ray imaging?

Dynamic real-time X-ray imaging demands short afterglow, and the reference point is caesium iodide doped with thallium, whose decay time sits around 1,000 nanoseconds. BrightLeaf is more than 140 times faster and shows no afterglow at all, because its decay time is only 7 nanoseconds. That places it on par with the organic scintillator and the fastest existing inorganic scintillator, making it a very promising candidate for high dynamic imaging.

BrightLeaf also shows excellent spatial resolution, and the explanation given is low scattering from the nanoparticle-based scintillator. In practice it easily allows a standard detector to resolve 100 micrometre feature sizes, the resolution required for almost all X-ray imaging applications, with a few exceptions such as mammography. The point is that an ordinary detector, not a specialised one, reaches that benchmark.

Ongoing work targets higher resolution still. The team is convinced that additional innovation in scintillation design, combined with perovskite quantum dot formulation, can substantially increase the 100 micrometre figure. Those two levers, how the scintillation is designed and how the quantum dots are formulated, are presented as the route beyond the current benchmark.

In this short video, you can learn:
* Thallium-doped caesium iodide has a decay time of about 1,000 nanoseconds, whereas the perovskite quantum dot film decays in only 7 nanoseconds and shows no afterglow.
* That 7 nanosecond decay is on par with the organic scintillator and the fastest existing inorganic scintillator.
* Low scattering from the nanoparticle-based scintillator lets a standard detector resolve 100 micrometre features, the requirement for almost all X-ray imaging apart from exceptions such as mammography.

đź“‹ **Clip Abstract** A perovskite quantum dot film scintillator decays in 7 nanoseconds with no afterglow, more than 140 times faster than thallium-doped caesium iodide at around 1,000 nanoseconds. Low nanoparticle scattering lets a standard detector resolve 100 micrometre features, and further scintillation design and quantum dot formulation work is expected to increase that resolution substantially.

About the speaker:
* Speaker: Behzad Shirmardi
* Company: BrightComSol GmbH
* Event: Quantum Dots 2021
* Location: Online

Join TechBlick - the home of frontier display technologies such as microLEDs, AR/VR, quantum dots, and beyond
https://www.techblick.com/

#PerovskiteQDScintillator, #SevenNanosecondDecay, #ZeroAfterglow, #HundredMicrometreResolution, #XRayImaging, #QuantumDots

This is a highlight of the presentation:

BrightLeave™ Perovskite QD Films As X-ray Scintillators

Quantum Dots 2021

​

12 May 2021

Online

Organised By:

TechBlick

​

More Highlights from the same talk.

05:12 - 07:22

How can printable scintillator resin escape the 50Ă—50 cm size limit of vapor-deposited cesium iodide detectors?

How can printable scintillator resin escape the 50Ă—50 cm size limit of vapor-deposited cesium iodide detectors?

Scintillators support indirect X-ray detection and are used in roughly 80% of X-ray detectors on the market, while accounting for about 20% of detector cost. Applications include healthcare, homeland security, defense, nuclear power plants, industrial inspection and research. The global scintillator market reached close to $500 million this year. The largest current X-ray detector is slightly smaller than 50 by 50 square centimeters.

One barrier is large-area scintillator manufacture. Cesium iodide scintillators are made by vapor deposition, a method described as very difficult to scale up for large-area production. That difficulty helps constrain detector formats: the biggest current X-ray detector is slightly smaller than 50 by 50 square centimeters. The speaker links this limit partly to the challenge of using large-area scintillators.

The approach is printing: BrightConsole can print the scintillator, and BrightSplash is a printable resin that can be made into a thin film at any dimension, so there is no size limitation. Work with partners uses roll-to-roll technology to make large-area scintillators as big as several square meters, creating X-ray imaging opportunities in areas that did not exist until recently.

In this short video, you can learn:
* Scintillators are used in approximately 80% of X-ray detectors on the market and account for approximately 20% of detector cost.
* Vapor deposition makes cesium iodide scintillators hard to scale to large areas, helping keep the largest X-ray detector slightly under 50 by 50 square centimeters.
* BrightSplash printable resin can form a thin film at any dimension, and roll-to-roll work targets large-area scintillators as big as several square meters.

đź“‹ **Clip Abstract** Printable scintillator resin offers a route beyond the roughly 50 by 50 cm limit of current X-ray detectors, which is tied to the difficulty of scaling vapor-deposited cesium iodide. BrightConsole printing and BrightSplash resin, combined with roll-to-roll large-area work, target thin films at any dimension and scintillators as large as several square meters.

About the speaker:
* Speaker: Behzad Shirmardi
* Company: BrightComSol GmbH
* Event: Quantum Dots 2021
* Location: Online

Join TechBlick - the home of frontier display technologies such as microLEDs, AR/VR, quantum dots, and beyond
https://www.techblick.com/

#CesiumIodide, #VaporDeposition, #RollToRoll, #LargeAreaScintillators, #XrayImaging, #Scintillators

09:46 - 12:06

What light output must perovskite QD films reach to cut patient X-ray dose?

What light output must perovskite QD films reach to cut patient X-ray dose?

Current BrightLeaf films have light output below 20,000 photons per mega electron volt. This is bright enough for industrial inspection, where scan time can be several seconds to achieve a reasonably bright image. It is not sufficient for medical applications, because X-ray dose must be kept as low as possible. Medical use currently relies on cesium iodide scintillators at around 56,000 photons per mega electron volt to keep exposure below 1 second.

Cesium iodide offers required light output but has drawbacks: high price, complicated fabrication, difficult integration with the factory, and long decay time. Recently published scientific papers report comparable and even higher light output for perovskite scintillators than for cesium iodide. The claim is that similar and even higher brightness than cesium iodide-based scintillators is achievable soon.

Perovskite has a high absorption cross-section for X-rays, and reaching cesium iodide-level brightness could reduce the X-ray dose for patients. The talk states that 2% of all cancers are believed to be caused by ionizing radiation during X-ray and gamma-ray imaging in the US alone. That dose concern is why the light-output gap matters for medical scintillators.

In this short video, you can learn:
* BrightLeaf films currently deliver below 20,000 photons per mega electron volt, enough for industrial inspection with scan times of several seconds but not for medical imaging.
* Cesium iodide at around 56,000 photons per mega electron volt keeps exposure below 1 second but brings high price, complicated fabrication/integration, and long decay time.
* Published papers report perovskite light output comparable to or higher than cesium iodide, and perovskite's high X-ray absorption cross-section could lower patient dose.

đź“‹ **Clip Abstract** BrightLeaf perovskite QD films currently produce below 20,000 photons per mega electron volt, sufficient for industrial inspection but not for low-dose medical X-ray imaging. Cesium iodide at around 56,000 photons per mega electron volt meets the sub-1-second exposure requirement, while published results and perovskite's high X-ray absorption cross-section suggest higher brightness and reduced patient dose may be achievable.

About the speaker:
* Speaker: Behzad Shirmardi
* Company: BrightComSol GmbH
* Event: Quantum Dots 2021
* Location: Online

Join TechBlick - the home of frontier display technologies such as microLEDs, AR/VR, quantum dots, and beyond
https://www.techblick.com/

#PerovskiteQDScintillators, #CesiumIodide, #LightOutputPerMeV, #XrayAbsorptionCrossSection, #MedicalImaging, #RadiationDetection


About this talk

→ BrightLeave™ Perovskite QD Films As X-ray Scintillators · Behzad Shirmardi · Quantum Dots: Material Innovations, Commercial Applications 2021

More Snippets
CONTACT US

KGH Concepts GmbH

Mergenthalerallee 73-75, 65760, Eschborn

+49 17661704139

admin@techblick.com

TechBlick is owned and operated by KGH Concepts GmbH

Registration number HRB 121362

VAT number: DE 337022439

  • LinkedIn
  • YouTube

Sign up for our newsletter to receive updates on our latest speakers and events AND to receive analyst-written summaries of the key talks and happenings in our events.

Thanks for submitting!

© 2026 by KGH Concepts GmbH

bottom of page