The scaling path runs on two lines: a 100 by 100 millimetre R&D format and a pilot-line T20 at 600 by 1200 millimetres. Critical processes are long-edge leading, with the perovskite layer deposited at a 1200-millimetre-wide web width to tackle scaling challenges now. For high-volume manufacturing, the distance is simply 4X’d, which is usually easier than changing the width.
Utility-scale customers cannot mount such a tiny panel onto a one-axis tracker, so four are co-framed into an approximately 1.2 by 2.4-metre panel, making pilot installations feel familiar. That co-framed format is not the long-term product. The next factory evolution moves to single-pane glass, using standard G12-type glass.
R&D has shown consistent progress in laboratory efficiency for perovskite alone and for tandem integrated modules. The team coats on glass and makes a mechanically stacked tandem: necessarily four-terminal in R&D, but voltage-matched two-terminal in product, with perovskite and silicon circuits tied in parallel in the junction box. 2025 was described as a banner year for outdoor durability.
In this short video, you can learn:
* The pilot line uses a 600 by 1200 millimetre T20 format with long-edge-leading processes and a 1200-millimetre perovskite web width.
* High-volume manufacturing scales by 4X’ing the web distance rather than changing width.
* R&D mechanically stacked tandems are four-terminal, while the product is voltage-matched two-terminal with parallel perovskite and silicon circuits in the junction box.
📋 **Clip Abstract** The scale-up uses a 100 by 100 millimetre R&D coupon format and a 600 by 1200 millimetre pilot-line T20, with critical processes long-edge leading at a 1200-millimetre perovskite web width. Utility-scale pilots co-frame four T20 panels into roughly 1.2 by 2.4 metres before a single-pane G12 glass factory evolution, while R&D tandems move from four-terminal mechanically stacked devices to voltage-matched two-terminal products.
About the speaker:
* Speaker: Colin Bailie
* Company: Tandem PV
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin
Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect
Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect
#LongEdgeLeading, #VoltageMatchedTwoTerminal, #MechanicallyStackedTandem, #G12Glass, #PerovskitePV, #TandemSolar
This is a highlight of the presentation:
Pursuing bankability for perovskite/silicon tandem panels
21 and 22 OCT 2026
Estrel, Berlin
Organised By:
More Highlights from the same talk.
06:55 - 08:50
What do real field temperatures and accelerated tests actually predict for perovskite outdoor performance?
What do real field temperatures and accelerated tests actually predict for perovskite outdoor performance?
Two years of back-of-module temperature data from a thin-film installation in Texas, where summers are generally 40°C, show 24/7 module temperatures peaking near 65°C and a typical arenas-corrected value around 40°C. This argues against assuming panels routinely reach 80°C or 100°C, reframing what acceleration means for outdoor lifetime prediction.
The field is aligning on a combination of tests. The ISO cell two test runs heat and light simultaneously under maximum-power-point conditions and has been bread-and-butter testing; a couple hundred modules can be tested in R&D, with consistent progress now matching performance expectations between pilot and R&D modules using the same ISO cell two T90s.
ISO cell two alone is not enough: UVID must be addressed, and UVID combined with ISO cell two has been relatively predictive of outdoor field performance. That matters for bankability because independent engineers want a holistic set of modeling when judging outdoor field performance.
In this short video, you can learn:
* A two-year Texas thin-film dataset shows back-of-module temperatures peaking near 65°C, with a typical arenas-corrected value around 40°C, not 80°C or 100°C.
* The ISO cell two test runs heat and light simultaneously at maximum power point and can be applied to a couple hundred R&D modules, with pilot and R&D modules matching on the same T90s.
* UVID combined with ISO cell two has been relatively predictive of outdoor field performance, which supports the holistic modeling independent engineers request for bankability.
📋 **Clip Abstract** Two years of Texas back-of-module data show peaks near 65°C and a typical arenas-corrected value around 40°C, challenging assumptions that panels routinely reach 80°C or 100°C. The approach pairs ISO cell two heat-and-light maximum-power-point testing across pilot and R&D modules with UVID, arguing that this combination is relatively predictive of outdoor performance and supports the holistic modeling independent engineers want for bankability.
About the speaker:
* Speaker: Colin Bailie
* Company: Tandem PV
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin
Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect
Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect
#BackOfModuleTemperature, #ISOCellTwo, #UVIDTesting, #T90Testing, #PerovskiteTandem, #SolarBankability
12:19 - 13:14
How does a dozen U.S. outdoor pilots feed into a preliminary bankability report?
How does a dozen U.S. outdoor pilots feed into a preliminary bankability report?
The route to bankability starts with about a dozen field pilots across the United States, selected to cover wet, dry, cold and hot conditions under a four-corners outdoor testing mentality. Those pilots begin at the end of this year, moving the programme into outdoor field testing.
In the first half of next year, the work shifts to product qualifications: standard IEC tests and PQP tests. This phase is timed to align, in the second half and towards the end of next year, with the preliminary bankability report.
That preliminary bankability report combines two evidence streams: the product qualifications and a full year of outdoor string-level pilot data across all relevant geographies. The report therefore joins qualification results with a full year of string-level field data across relevant geographies.
In this short video, you can learn:
* About a dozen U.S. pilots are planned across wet, dry, cold and hot conditions, starting at the end of this year.
* Standard IEC and PQP product qualifications are scheduled for the first half of next year.
* A preliminary bankability report is targeted for late next year, combining those qualifications with a full year of outdoor string-level pilot data.
📋 **Clip Abstract** The plan uses about a dozen U.S. outdoor pilots spanning wet, dry, cold and hot conditions, beginning at the end of this year. Standard IEC and PQP qualifications in the first half of next year are timed to feed a preliminary bankability report late next year that combines those results with a full year of string-level pilot data.
About the speaker:
* Speaker: Colin Bailie
* Company: Tandem PV
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin
Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect
Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect
#FourCornersTesting, #IECPQPQualification, #StringLevelPilotData, #PreliminaryBankabilityReport, #PerovskiteSolarCells, #TandemPhotovoltaics
09:23 - 11:42
Why do shaded perovskite circuits in parallel get driven into damaging forward bias rather than reverse bias?
Why do shaded perovskite circuits in parallel get driven into damaging forward bias rather than reverse bias?
Outdoor durability at maximum power point, 24 hours a day and seven days a week, is the primary bankability case, but development must also address edge cases. Reverse bias is familiar for cells and circuits in series and can be damaging to perovskite solar cells. With parallel circuits—perovskite circuits in parallel and those in parallel with silicon—different shade events can drive reverse current.
The shaded panels remain at positive voltage rather than negative voltage, so the condition resembles running a panel under electroluminescence conditions for long periods with full-sun injection. Similar behavior can occur at utility scale when multiple strings connect to one central inverter: if one string is shaded, it is driven in reverse current, meaning positive voltage. These are different degradation modes from the maximum-power-point case.
Once single panels and single circuits in R&D and pilot are working well from a longevity standpoint, these edge cases become more and more important. Both reverse-bias and forward-bias conditions therefore need attention. For reverse current, recent work has become good at ensuring stability against that forward-bias condition, while parallel-circuit shading remains part of edge-case development.
In this short video, you can learn:
* Shade events can drive reverse current through parallel perovskite circuits, leaving shaded panels at positive rather than negative voltage.
* That positive-voltage condition resembles long electroluminescence operation with full-sun injection and is a different degradation mode.
* Utility-scale strings on a central inverter can see the same shaded-string reverse current, so edge cases matter once R&D and pilot circuits show longevity.
📋 **Clip Abstract** Bankability requires maximum-power-point durability plus edge-case testing. The discussion contrasts series reverse bias with parallel-circuit shaded forward-bias conditions, including utility-scale strings on a central inverter, and notes recent progress on stability against forward bias as edge cases gain importance after R&D and pilot longevity.
About the speaker:
* Speaker: Colin Bailie
* Company: Tandem PV
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin
Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect
Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect
#PerovskiteCircuits, #ForwardBias, #ReverseCurrent, #CentralInverter, #PerovskitePhotovoltaics, #SolarModuleDurability
About this talk
→ Pursuing bankability for perovskite/silicon tandem panels · Colin Bailie · Perovskite Connect 2026