Jefford Humes | Raymor/NanoIntegris Technologies: How can a selective polymer wrap only semiconducting nanotubes while leaving metallic and carbon impurities behind?

10:55 - 13:10

Other snippets from this talk

Summary of the clip:

How can a selective polymer wrap only semiconducting nanotubes while leaving metallic and carbon impurities behind?

Single-walled nanotubes are most effective when dispersed into solution, but achieving that dispersion is challenging. Chemicals such as bile acids can wrap nanotubes and disperse them. That solves dispersion, yet the resulting single-walled nanotube solution still contains multiple components: semiconducting nanotubes, metallic single-walled nanotubes, carbonaceous impurities and metallic impurities. These mixed populations must be addressed before separation.

To separate these species, density gradient ultracentrifugation or chromatography can be used, processes that may take many hours or many days. As an alternative, selective polymers such as dialkylfluorine homopolymers can disperse the nanotubes. Up to date, they cannot be dispersed into an aqueous solution, but they can be dispersed into aromatic solutions. When applied to those solutions with a little centrifugation, the selective polymer approach is intended to isolate semiconducting material.

What has been found is that the selective polymer wraps only the semiconducting materials in solution. With the small amount of centrifugation, the process separates carbon impurities, metallic impurities and metallic nanotubes. The result is a solution left behind that contains the semiconducting nanotubes rather than the mixed population. This is the key selectivity claim: the polymer distinguishes semiconducting nanotubes from metallic nanotubes and from the other impurities present after bile-acid dispersion.

In this short video, you can learn:
* Bile acids enable single-walled nanotube dispersion, but the resulting solution still contains semiconducting nanotubes, metallic nanotubes, carbonaceous impurities and metallic impurities.
* Density gradient ultracentrifugation or chromatography can separate these components, though the process may take many hours or many days.
* Dialkylfluorine homopolymers in aromatic solution, with a little centrifugation, wrap only semiconducting nanotubes and separate carbon impurities, metallic impurities and metallic nanotubes.

📋 **Clip Abstract** Bile acids can disperse single-walled nanotubes, yet the dispersion remains a mixture of semiconducting nanotubes, metallic nanotubes, carbonaceous impurities and metallic impurities. Density gradient ultracentrifugation or chromatography can take many hours or days, while selective dialkylfluorine homopolymers disperse in aromatic solutions and, with a little centrifugation, wrap only semiconducting nanotubes while separating carbon impurities, metallic impurities and metallic nanotubes.

About the speaker:
* Speaker: Jefford Humes
* Company: Raymor/NanoIntegris Technologies
* Event: Graphene, CNTs & 2D Materials: Users, Applications, Major Producers & Start Ups
* Location: online

#SingleWalledNanotubes, #BileAcidDispersion, #DensityGradientUltracentrifugation, #DialkylfluorineHomopolymer, #CarbonNanotubes, #2DMaterials

This is a highlight of the presentation:

Industrial Provider of High-Purity Carbon Nanotubes and Graphene for Electronic Applications

Graphene, CNTs & 2D Materials: Users, Applications, Major Producers & Start Ups

​

26-27 April 2022

Online

Organised By:

TechBlick

​

More Highlights from the same talk.

18:45 - 20:12

Which flake, purity and dispersion specs define few-layer graphene for lithium-ion batteries?

Which flake, purity and dispersion specs define few-layer graphene for lithium-ion batteries?

The graphene is described as 3 to 7 layers with good G/D ratios, surface area up to 500 m²/g, flake size of 150 to 200 nm and average flake thickness of about 2.4 nm. It is thermally stable, has low oxygen content of 1 to 2% and very low metal content below 200 ppm. These are the flake and purity specs presented.

Its turbostratic structure means the layers are not aligned, and this may be dispersed very effectively into solution, as shown by very low instability indexes. The material is provided mainly as a powder or in an aqueous dispersion, with dispersion levels up to 8 to 10 weight percent, described as industry-leading. These dispersion and structure characteristics are the ones presented.

In lithium-ion batteries, the turbostratic structure, where layers are not aligned, is said to solve a big problem. During charge and discharge, silica expands and contracts, degrading the battery’s ability over time. The graphene is also listed for flexible displays, supercapacitors and polymer composites, extending its application range beyond batteries.

In this short video, you can learn:
* The graphene has 3–7 layers, surface area up to 500 m²/g, 150–200 nm flakes and about 2.4 nm average flake thickness.
* Purity is indicated by 1–2% oxygen and less than 200 ppm metal content, with a thermally stable turbostratic structure.
* It is supplied as powder or aqueous dispersion up to 8–10 wt%, with low instability indexes and listed uses including lithium-ion batteries, supercapacitors, flexible displays and polymer composites.

📋 **Clip Abstract** Few-layer graphene is specified at 3–7 layers, 150–200 nm flake size, about 2.4 nm thickness, surface area up to 500 m²/g, 1–2% oxygen and less than 200 ppm metals. Its turbostratic, non-aligned layers enable effective dispersion, including aqueous dispersions up to 8–10 wt%, and address expansion/contraction degradation in lithium-ion batteries.

About the speaker:
* Speaker: Jefford Humes
* Company: Raymor/NanoIntegris Technologies
* Event: Graphene, CNTs & 2D Materials: Users, Applications, Major Producers & Start Ups
* Location: online

#FewLayerGraphene, #TurbostraticStructure, #AqueousDispersion, #LithiumIonBatteries, #CarbonNanotubes, #2DMaterials

00:03:14 - 00:04:58

How do you extract pure semiconducting carbon nanotubes from a chaotic raw mix of metallic and carbonaceous impurities?

How do you extract pure semiconducting carbon nanotubes from a chaotic raw mix of metallic and carbonaceous impurities?

Raw single-walled carbon nanotubes (SWCNTs) synthesized via chemical vapor deposition, arc discharge, or plasma reactors are always a highly disorganized mixture. Typically, these materials emerge as 70% semiconducting and 30% metallic, a combination that renders them unusable for high-end electronics without further processing. To overcome this, sophisticated sorting methodologies are required to isolate the pure electrical properties of individual species.

NanoIntegris utilizes advanced physical and chemical separation processes to isolate high-purity fractions. By deploying density gradient ultracentrifugation (DGU), selective polymerization, and chromatography, researchers can systematically strip away carbonaceous debris, metal catalysts, and metallic-nature tubes. This results in highly enriched, electronic-grade semiconducting or metallic solutions exceeding 99% purity.

The final validation of these materials relies on rigorous metrology, with a strong emphasis on real-world functional analysis. While spectral analysis and electron microscopy offer detailed structural feedback, the ultimate standard of purity is proven through active device fabrication. Building thin-film transistors (TFTs) directly from these enriched solutions provides the definitive measure of charge transport performance.

In this short video, you can learn:
* The post-synthesis purification techniques used to eliminate metal catalysts and amorphous carbon.
* How density gradient ultracentrifugation and selective polymerization separate metallic from semiconducting nanotubes.
* Why thin-film transistor fabrication serves as the gold standard for verifying CNT electronic purity.
📋 **Clip Abstract** This clip explains the complex chemical and physical processes required to sort raw carbon nanotubes into high-purity metallic and semiconducting fractions. It highlights the transition from mixed raw materials to 99%+ pure electronic-grade solutions validated through device testing.

#SingleWalledCarbonNanotubes, #DensityGradientUltracentrifugation, #SemiconductingNanotubes, #ThinFilmTransistors, #PrintedElectronics, #FlexibleElectronics

07:35 - 08:42

What specs do plasma SWCNTs leave the reactor with, and what mixture limits direct electronics use?

What specs do plasma SWCNTs leave the reactor with, and what mixture limits direct electronics use?

The on-site radio-frequency plasma reactor takes carbon powder as carbon black combined with metal catalyst and generates relatively high-purity single-wall carbon nanotubes. As-made material exits at about 70% purity, with diameters from 0.9 to 1.7 nanometers and lengths spanning roughly 300 nanometers to 4 microns. Raman spectroscopy gives G/D ratios of about 34 to 40, which the speaker cites as another indication of purity.

The stated limitation is the mixture: the nanotubes are described as a mix of both metallic nanotubes and another type. That mixture is the only issue the speaker highlights when discussing direct use, so the as-made powder cannot be treated as a single nanotube population. The clip ends just as the speaker begins to describe the metallic fraction.

The provider can take material from different carbon-nanotube sources, not just one reactor. The clip references iso-nanotubes S and M as items listed for later slides, but it does not give their specifications here. The RF plasma route is presented as one such source: carbon black plus metal catalyst in, single-wall nanotubes out, with the measured purity, diameter, length and G/D values above.

In this short video, you can learn:
* The on-site RF plasma reactor converts carbon black plus metal catalyst into single-wall carbon nanotubes at about 70% purity.
* As-made plasma SWCNTs measure 0.9–1.7 nm in diameter, 300 nm–4 µm in length, and G/D 34–40 by Raman.
* The stated issue is that the nanotubes are a mixture including metallic tubes, so the as-made material is not a single electronic type.

📋 **Clip Abstract** As-made single-wall carbon nanotubes from an on-site radio-frequency plasma reactor are about 70% pure, with 0.9–1.7 nm diameters, 300 nm–4 µm lengths and Raman G/D ratios of 34–40. The speaker identifies the metallic-containing nanotube mixture as the limitation for direct use, while noting that material can come from different carbon-nanotube sources.

About the speaker:
* Speaker: Jefford Humes
* Company: Raymor/NanoIntegris Technologies
* Event: Graphene, CNTs & 2D Materials: Users, Applications, Major Producers & Start Ups
* Location: online

#PlasmaSWCNTs, #CarbonBlackCatalyst, #RamanGD, #IsoNanotubesSM, #CarbonNanotubes, #Graphene2D


About this talk

→ Industrial Provider of High-Purity Carbon Nanotubes and Graphene for Electronic Applications · Jefford Humes · Graphene, CNTs & 2D Materials: Users, Applications, Major Producers & Start Ups 2022


Other talks by Jefford Humes


More highlights from Jefford Humes

More Snippets
CONTACT US

KGH Concepts GmbH

Mergenthalerallee 73-75, 65760, Eschborn

+49 17661704139

admin@techblick.com

TechBlick is owned and operated by KGH Concepts GmbH

Registration number HRB 121362

VAT number: DE 337022439

  • LinkedIn
  • YouTube

Sign up for our newsletter to receive updates on our latest speakers and events AND to receive analyst-written summaries of the key talks and happenings in our events.

Thanks for submitting!

© 2026 by KGH Concepts GmbH

bottom of page