top of page

Kedar Sathaye

KONICA MINOLTA SENSING EUROPE B.V.

* All members of the platform can watch the entire presentation.

 

Please register to become a member.

Kedar Sathaye | KONICA MINOLTA SENSING EUROPE B.V.: Why do standard camera lenses cause a "knot hole effect" when measuring near-to-eye displays?

00:05:52 - 00:07:42

Other snippets from this talk

Summary of the clip:

Why do standard camera lenses cause a "knot hole effect" when measuring near-to-eye displays?

Testing near-to-eye displays presents unique optical challenges because traditional imaging lenses place their optical aperture deep inside the lens barrel. For an accurate measurement of what a user sees, the entrance pupil of the camera lens must be located externally at the front of the lens, matching the physical position of the human eye's pupil.

Using standard camera lenses leads to a severe optical limitation known as the knot hole effect. Because the aperture is buried inside, the display's field of view is artificially clipped, preventing the camera from capturing the full spatial extent of the projected augmented or virtual reality environment.

Furthermore, typical industrial lenses are too bulky to fit within the tight mechanical constraints of headset eye-relief distances. Replicating human vision requires specialized optics designed to position an external entrance pupil precisely at the headset's nominal eye position.

In this short video, you can learn:
* Why the internal aperture location of standard lenses causes the knot hole effect and clips the field of view
* The importance of positioning the camera's entrance pupil at the physical front of the lens stack
* How bulkiness and low spatial resolution limit standard optical test equipment in microdisplay metrology

📋 **Clip Abstract** Discover why conventional camera lenses are fundamentally unsuited for testing near-to-eye virtual and augmented reality displays. This clip details the optical physics behind the knot hole effect and outlines the necessity of front-aperture lens designs.

#KnotHoleEffect, #FrontApertureLens, #NearToEyeDisplayMetrology, #EntrancePupilMatching, #ARVROptics, #MicrodisplayMetrology

This is a highlight of the presentation:

​

Printed Electronics Innovation Day 2024

Display Innovation Day 2024

​

TechBlick | Online Platform

Organised By:

TechBlick

​

More Highlights from the same talk.

02:15 - 03:47

How much luminance and color variation appears across a 2 cm microLED display?

How much luminance and color variation appears across a 2 cm microLED display?

The non-uniformity challenge begins at pixel level, where luminance variance appears across the display. MicroLED is described as mature but still improving, and uniformity on the luminance level remains a challenge. Displays measured show wide luminance variance because they are extremely bright — easily from 50,000 to 60,000 candela per square meter on a single display less than two centimeters in size.

Such individual pixel variation is of course challenging to manufacturers, because it appears within one small panel rather than between separate displays. Then there is color dependency: variation of 0.01 was seen on the CIE 1931 curve, so significant color differences appear across the display. And this is a display just two centimeters long, which is again a challenge for metrology as well as for the manufacturers.

What does this mean for measurement? Both the luminance spread — 50,000 to 60,000 candela per square meter — and the 0.01 color shift on CIE 1931 must be captured at pixel level before any correction can be applied, and the two-centimeter format makes that a tight metrology problem for manufacturers and measurement engineers alike. Three minutes of correction logic rest on getting these two numbers right first.

In this short video, you can learn:
* One microLED display under two centimeters can carry luminance from 50,000 to 60,000 candela per square meter.
* Color dependency adds variation of 0.01 on the CIE 1931 curve across that same small display.
* The non-uniformity is a challenge for metrology and for manufacturers, and correction follows measurement.

📋 **Clip Abstract** Pixel-level luminance spread of 50,000 to 60,000 candela per square meter and color variation of 0.01 on CIE 1931 are both measured within a single microLED display under two centimeters. These variances are framed as a challenge for metrology and for manufacturers, with measurement presented as the step before correction.

About the speaker:
* Speaker: Kedar Sathaye
* Company: Konica Minolta
* Event: MicroLED Connect 2024
* Location: High Tech Campus, Eindhoven, Netherlands

Join the most event MicroLED, AR/VR display and Optical I/O Connect event of the year
Learn more https://www.microledconnect.com/

#MicroLEDUniformity, #LuminanceVariation, #CIE1931ColorShift, #PixelLevelMetrology, #DisplayMetrology, #EmissiveDisplays

07:46 - 09:45

Can fractional-pixel measurement and correction coefficients improve yield on already-manufactured microLED displays?

Can fractional-pixel measurement and correction coefficients improve yield on already-manufactured microLED displays?

The fractional-pixel method addresses a basic sensor-coverage limitation: when pixels are not fully covered by the sensor, the traditional approach struggles for accuracy and the fill factor remains zero. Fractional-pixel measurement does not depend on that coverage, so it can still compute accurately how the pixels will be tested. This is presented as a software-level method for microLED displays viewed through a microscope.

Uniformity measurement is not limited to a single metric. The discussed techniques cover uniformity and grid placement, and they adapt to pincushion/barrel and other distortion types. That matters for microLED displays measured with a microscope, where software must handle those distortions before judging pixel behavior. The talk frames these capabilities as software-level, building on the fractional-pixel approach rather than requiring a change to the already-manufactured display.

Correction coefficients, already applied on big billboards, can be applied similarly to microLEDs. The significant claim is that an already-manufactured display can be corrected at wafer level, described as a step in the right direction to improve yield. An example shows luminance improving, and the same applies to bright color. Pixel-level and wafer-level correction can limit waste and safeguard efficiency.

In this short video, you can learn:
* Fractional-pixel measurement works even when sensor coverage is incomplete, unlike traditional methods where fill factor remains zero.
* Grid-placement and uniformity techniques adapt to pincushion/barrel and other distortions for microscope-based microLED measurement.
* Correction coefficients can be applied at wafer level to already-manufactured microLED displays, improving luminance and yield while limiting waste.

📋 **Clip Abstract** Fractional-pixel measurement enables accurate testing of microLED pixels even when sensor coverage is incomplete, while software handles uniformity, grid placement and distortion. Correction coefficients, analogous to billboard correction, can then be applied at wafer level to already-manufactured displays, with luminance improvements and yield gains described.

About the speaker:
* Speaker: Kedar Sathaye
* Company: Konica Minolta
* Event: MicroLED Connect 2024
* Location: High Tech Campus, Eindhoven, Netherlands

Join the most event MicroLED, AR/VR display and Optical I/O Connect event of the year
Learn more https://www.microledconnect.com/

#FractionalPixelMethod, #CorrectionCoefficients, #MicroLEDUniformity, #WaferLevelYield, #MicroLEDDisplays, #DisplayMetrology

04:01 - 06:08

How much wavelength spread appears across a monochromatic microLED display, and what camera resolution is needed?

How much wavelength spread appears across a monochromatic microLED display, and what camera resolution is needed?

Spectral variation appears at emitter level and therefore at display level: a single monochromatic display can show three different wavelengths, exaggerated here from 510 to 580 nm. Manufacturers would not ship that spread, but measured variation of 3 to 5 nm, sometimes 10 nm, is seen across a display. This shifts the uniformity problem beyond mura alone to wavelength-dependent correction.

The proposed approach is called ura, a Japanese term for defect, meaning removal of defects. At hardware level this requires high-resolution cameras and microscopic lenses so each individual pixel can be seen and measured properly. The measurement must resolve the pixel itself, not an average across neighboring emitters, because spectral and spatial non-uniformities need to be captured before correction.

Camera pixel budgeting is explicit: normally three to five camera pixels are required for one display pixel. For a one-micron microLED, five camera pixels means 0.2 micron per camera pixel. That resolution is described as achievable with a high-resolution camera, linking measurable wavelength spread and single-pixel defect removal to the optics and sensor specification rather than to display-level averages.

In this short video, you can learn:
* Measured wavelength variation across a monochromatic microLED display is typically 3 to 5 nm and can reach 10 nm.
* The ura approach treats defects for removal and depends on high-resolution cameras with microscopic lenses to measure individual pixels.
* At one-micron microLED size, five camera pixels per display pixel require 0.2-micron camera pixel resolution.

📋 **Clip Abstract** Spectral variation on a monochromatic microLED display can span 3 to 5 nm, sometimes 10 nm, even though a 510-to-580-nm example is exaggerated. Correcting such defects with the ura approach requires microscopic lenses and high-resolution cameras, with three to five camera pixels per display pixel and 0.2-micron resolution for a one-micron emitter.

About the speaker:
* Speaker: Kedar Sathaye
* Company: Konica Minolta
* Event: MicroLED Connect 2024
* Location: High Tech Campus, Eindhoven, Netherlands

Join the most event MicroLED, AR/VR display and Optical I/O Connect event of the year
Learn more https://www.microledconnect.com/

#MicroLEDUniformity, #SpectralVariation, #CameraPixelResolution, #DefectRemoval, #EmissiveDisplays, #DisplayMetrology

More Snippets
CONTACT US

KGH Concepts GmbH

Mergenthalerallee 73-75, 65760, Eschborn

+49 17661704139

admin@techblick.com

TechBlick is owned and operated by KGH Concepts GmbH

Registration number HRB 121362

VAT number: DE 337022439

  • LinkedIn
  • YouTube

Sign up for our newsletter to receive updates on our latest speakers and events AND to receive analyst-written summaries of the key talks and happenings in our events.

Thanks for submitting!

© 2026 by KGH Concepts GmbH

bottom of page