Ludovic Serex | Neurosoft Bioelectronics SA: How do we scale the fabrication of tissue-soft neural implants using semiconductor manufacturing techniques?
00:04:11 - 00:05:05
Other snippets from this talk
Summary of the clip:
How can we transition implantable neural interfaces from hand-assembled novelties to high-yield, wafer-scale microfabrication?
The translation of bioelectronic interfaces from laboratory scale to clinical application requires a shift in manufacturing philosophy. By leveraging polydimethylsiloxane (PDMS)—a medical-grade silicone elastomer with an extensive history of biocompatibility—as a structural substrate, researchers can bypass the regulatory hurdles associated with unproven polymers. The core innovation lies not in the introduction of exotic materials, but in the radical redesign of how this elastomer is patterned and processed.
To achieve high-resolution electrode arrays, traditional manual assembly is replaced with automated blade coating and thin-film gold evaporation techniques adapted from the semiconductor industry. This transition to wafer-scale processing minimizes human intervention, drastically reducing defect rates while ensuring geometric reproducibility across microelectrode sites. The integration of photolithographic precision with elastomer processing allows for the high-throughput fabrication of mechanically compliant neural interfaces.
By optimizing these microfabrication workflows, the cost-to-performance ratio of high-density electrode arrays is significantly improved. Scalable manufacturing yields superior spatial resolution and mechanical matching to soft tissue without escalating production costs. This proprietary fabrication paradigm is secured by a robust portfolio of patents, positioning the technology to redefine the commercial landscape of soft bioelectronics.
In this short video, you can learn:
* How medical-grade PDMS is repurposed using advanced microfabrication workflows.
* The role of wafer-scale processing, blade coating, and gold evaporation in reducing manual labor.
* How scalable manufacturing achieves superior electrode precision at a competitive cost.
📋 **Clip Abstract** The speaker discusses the fabrication of advanced electrode devices using medical-grade PDMS processed via wafer-scale blade coating and gold evaporation. This patented manufacturing approach reduces manual labor and increases device precision while maintaining cost parity with traditional methods.
🎤 Speaker: Ludovic Serex
🏢 Company: Neurosoft Bioelectronics SA
📅 Event: The Future of Electronics RESHAPED 2023 Berlin
📍 Location: Estrel Congress Centre, Berlin, Germany, Europe
🌐 Learn more at the next TechBlick event: https://www.techblick.com
#PDMSMicrofabrication, #WaferScaleBladeCoating, #GoldMetallization, #SoftNeuralImplants, #BrainComputerInterfaces, #FlexibleBioelectronics
This is a highlight of the presentation:
More Highlights from the same talk.
04:55 - 06:48
Why swap platinum wires and rigid silicone for cracked thin-film gold and a nanoparticle composite?
Why swap platinum wires and rigid silicone for cracked thin-film gold and a nanoparticle composite?
The starting point is the silicone already used in the clinic, but softer — the difference between a rigid tire elastomer and a chewing-gum-like elastic one. The same type of silicone is kept, only made a little more soft, and on top of it the standard electrical wire is replaced. That softer base is what the rest of the electrode stack is built onto.
Instead of a normal electrical wire, a very, very thin layer of gold is deposited as the conductor — deposited so that it forms many macro cracks, visible in the pictures. Those cracks let the metal deform out of plane, so the gold becomes stretchable while remaining conductive. For the electrode pad, platinum is replaced by a composite of platinum nanoparticles mixed into the silicone matrix, giving a fully stretchable implant.
Fabrication takes a page from the textbooks of micro manufacturing: layer-by-layer manufacturing adds each component in turn. A first layer puts down the silicone, then a layer carries the gold tracks, then a layer carries the numbering embedded into the implant, and further layers add the composite. Once ready, the implant is removed from its wafer carrier and simply connected with the lead.
In this short video, you can learn:
* Macro cracks in a thin gold film let the metal deform out of plane, so it stays conductive while stretching.
* Mixing platinum nanoparticles into the silicone matrix replaces a solid platinum pad and makes the whole implant stretchable.
* Layer-by-layer micro manufacturing builds silicone, gold tracks, embedded numbering and composite pads before the device is lifted off its wafer carrier.
📋 **Clip Abstract** Soft implantable electrodes are built on a softer grade of clinical silicone, with cracked thin-film gold tracks and platinum-nanoparticle composite pads replacing wires and solid platinum contacts. Layer-by-layer micro manufacturing stacks silicone, gold, numbering and composite, after which the implant is released from its wafer carrier and connected to the lead.
About the speaker:
* Speaker: Ludovic Serex
* Company: Neurosoft Bioelectronics
* Event: Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
* Location: Online
Join TechBlick - for the leading global event on wearable electronics
https://www.techblick.com/
#CrackedGoldThinFilm, #PlatinumNanoparticleComposite, #SoftSiliconeElastomer, #LayerByLayerFabrication, #StretchableElectronics, #ImplantableElectrodes
13:24 - 15:30
Can a soft electrode fold into a brain sulcus and still image cleanly on CT and MRI?
Can a soft electrode fold into a brain sulcus and still image cleanly on CT and MRI?
On a cadaveric human brain specimen, the soft electrodes conformed closely to the brain surface, while clinical implants required pushing to make contact. The surgeons then split a sulcus slightly without damaging tissue, folded the electrode in half, and inserted it inside the sulcus. The implant showed two folding directions: one onto itself and one along the sulcus.
Because the electrode must bend in two directions—onto itself and along the sulcus—the design requires stretchability. The speaker states this approach is absolutely not possible with the implants used in the clinic today. This is the key mechanical distinction demonstrated by the cadaveric insertion: conformal contact and sulcus folding depend on stretchable, thin electrode construction.
Imaging compatibility was also shown. The electrode sites are perfectly visible on a CT scan conforming to the implant. With MRI, using very thin materials, there were no huge artifacts, so the implant's location on the brain can be seen exactly. These advantages motivated the first use case for this electrode.
In this short video, you can learn:
* Soft electrodes conformed to a cadaveric human brain without the pushing needed for clinical implants.
* A surgeon split a sulcus without tissue damage, folded the electrode in half, and inserted it inside.
* Two-directional bending required stretchability, and thin materials allowed CT visibility and MRI with no huge artifacts.
📋 **Clip Abstract** A cadaveric human brain test showed soft electrodes conforming to the surface and folding into a split sulcus, unlike clinical implants that require pushing for contact. The two-directional folding required stretchability, while CT showed electrode sites clearly and MRI with thin materials produced no huge artifacts.
About the speaker:
* Speaker: Ludovic Serex
* Company: Neurosoft Bioelectronics
* Event: Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
* Location: Online
Join TechBlick - for the leading global event on wearable electronics
https://www.techblick.com/
#SoftImplantableElectrodes, #SulcusFolding, #CTVisibleElectrodes, #MRIArtifacts, #NeuralInterfaces, #BrainComputerInterfaces
08:14 - 10:32
Does implant softness really change the foreign-body response, or is crushed tissue tolerable?
Does implant softness really change the foreign-body response, or is crushed tissue tolerable?
A rat spinal cord comparison runs three conditions: surgery only with nothing implanted, soft electrodes, and a rigid electrode — not the extremely rigid clinical ones, but the already better polyimide type. Under mechanical strain the rigid implants visibly crush the spinal cord, whereas with no implant or very soft implants the electrode conforms to the cord, not the cord to the electrode.
The counter-argument is that the body is a compliant, resilient system, so if the spinal cord still works while slightly crushed, is it really a problem? It is, because the body notices the crushing: the foreign-body reaction kicks in and tries to kick the implant out. Because it is too big, it cannot, so it encapsulates the implant to isolate it from the body completely.
Encapsulation can break the implant, but even a still-working device is pushed further from the neural tissue. Recording becomes less precise; stimulation is less precise and needs more power to drive through the encapsulation layer, draining the battery of the implanted device. This is a huge problem, and it happens within a couple of months — which is why more compliant implants matter.
Soft implants conform to the spinal cord surface instead of crushing it under mechanical strain, unlike rigid polyimide devices.
Rigid implants trigger a foreign-body reaction that encapsulates the device because it is too big to be expelled.
Encapsulation degrades recording precision, raises stimulation power through the capsule layer and drains the battery within months.
In this short video, you can learn:
* Rigid polyimide implants crush the spinal cord under mechanical strain, while soft implants conform to the tissue surface.
* The foreign-body reaction cannot expel an oversized rigid implant, so it encapsulates it and isolates it from the body.
* Encapsulation moves the electrode away from neural tissue, worsening recording and stimulation precision and increasing power draw within a couple of months.
📋 **Clip Abstract** A rat spinal cord study compares no implant, soft electrodes and rigid polyimide electrodes, showing that rigid devices crush tissue under mechanical strain while soft ones conform to it. The resulting foreign-body reaction encapsulates the implant, degrading recording and stimulation precision and forcing higher stimulation power through the capsule layer within months.
About the speaker:
* Speaker: Ludovic Serex
* Company: Neurosoft Bioelectronics
* Event: Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
* Location: Online
Join TechBlick - for the leading global event on wearable electronics
https://www.techblick.com/
#ForeignBodyReaction, #PolyimideElectrodes, #SpinalCordImplants, #EncapsulationLayer, #NeuralInterfaces, #ImplantableElectronics
Other talks by Ludovic Serex
- Soft Implantable Electrodes to Interface with the Brain a Gateway to BCI · The Future of Electronics RESHAPED | Berlin 2023
- Soft Implantable Electrodes to Interface with the Brain · Wearable Sensors & Continuous Vital Signs Monitoring 2021
More highlights from Ludovic Serex
- ▶ Why does making a brain implant too soft compromise a neurosurgeon’s haptic feedback? · The Future of Electronics RESHAPED 2023 Berlin
- ▶ How do ultra-soft neural implants mitigate the chronic foreign body response in the brain? · The Future of Electronics RESHAPED 2023 Berlin
- ▶ Why swap platinum wires and rigid silicone for cracked thin-film gold and a nanoparticle composite? · Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
- ▶ Does implant softness really change the foreign-body response, or is crushed tissue tolerable? · Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
- ▶ Can a soft electrode fold into a brain sulcus and still image cleanly on CT and MRI? · Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
- ▶ Can a probe in the sulcus break the neural feedback loop that creates tinnitus? · Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021