top of page

Mark D. Poliks

Binghamton University

* All members of the platform can watch the entire presentation.

 

Please register to become a member.

Mark D. Poliks | Binghamton University: How do you prove a flexible medical patch can survive the intense vibrations of an emergency aircraft transport?

00:10:21 - 00:11:23

Other snippets from this talk

Summary of the clip:

How do you prove a flexible medical patch can survive the intense vibrations of an emergency aircraft transport?

A critical requirement for any device intended for aeromedical use is the ability to withstand severe environmental stressors without compromising performance. The system was subjected to the six-mode human vibration test, a standard protocol that simulates the intense, multi-axis vibrations experienced during the transport of patients in aircraft. This demanding validation is essential to ensure that the vital sign readings remain accurate and uninterrupted in a high-stakes emergency environment.

The testing was performed both at the Air Force Research Laboratory and in-house at Binghamton University, using specialized vibration systems. The flexible patches were subjected to vibrations in both horizontal and vertical configurations to comprehensively assess their response. This rigorous methodology aimed to identify any potential failure modes or signal degradation caused by the mechanical stress of a simulated flight.

The results demonstrated a key advantage of the flexible, low-modulus design. The lightweight patch did not couple with the severe vibrations; in fact, it effectively damped them. The system's performance was unaffected, and the only electrical noise detected was an artifact from the vibration table's motors interfering with the sensitive ECG signal, not a failure of the device itself. This proved the intrinsic robustness of the flexible hybrid electronics approach for harsh-environment applications.

In this short video, you can learn:
* The specific requirements of the six-mode human vibration test for aeromedical devices.
* Why low-modulus, lightweight flexible electronics are inherently robust to intense vibration.
* How printed electronic systems on soft substrates can act as vibration dampers, a key advantage over rigid electronics.
πŸ“‹ **Clip Abstract** This segment focuses on the validation of a flexible vital sign monitor for the extreme environment of aeromedical transport. It details the six-mode human vibration test and reveals the key finding that the low-modulus patch is not only immune to intense vibration but can even act as a damper.
πŸ”— Link in comments πŸ‘‡

#FlexibleElectronics, #VibrationTesting, #AeromedicalDevices, #VibrationDamping, #WearableElectronics, #MedicalDevices

This is a highlight of the presentation:

The Future of Electronics RESHAPED 2024

23-24 OCT 2024

Estrel Congress Centre, Berlin, Germany

Organised By:

TechBlick

More Highlights from the same talk.

00:06:03 - 00:07:37

Can printed electronics on flimsy plastic survive being brutally creased and bent hundreds of times?

Can printed electronics on flimsy plastic survive being brutally creased and bent hundreds of times?

The adjustable lead sets for this vital sign monitor are constructed from thermoplastic polyurethane (TPU), a flexible and stretchable plastic. The design incorporates multiple printed layers, with the conductive traces being the most critical. A key challenge is ensuring these printed circuits remain functional despite the flimsy nature of the substrate, which can be easily bent, stretched, and creased during handling and application, especially in rugged field conditions.

To accommodate different body sizes and movements, the design incorporates serpentine elastic connectors within the leads. These structures, which can be made with printed conductors or by integrating fine wires, allow for significant stretchability, enabling a "pull-to-fit" functionality. However, this added flexibility introduces more complex interconnects and potential points of failure, making robust design and manufacturing paramount to ensure consistent electrical performance.

Extensive reliability testing was conducted to validate the design's durability. Standard bending tests on INSTRON and MTS systems showed the leads were robust to hundreds of cycles. More impressively, extreme crease testsβ€”where the leads were sharply folded up to 50 times in the same location or held in a creased position for 24 hoursβ€”demonstrated that the laminated structure was exceptionally resilient, proving the viability of this printed electronics approach for demanding, real-world applications.

In this short video, you can learn:
* How serpentine structures enable stretchability in printed circuits on flexible substrates.
* The multi-layer lamination process used to create robust, encapsulated flexible leads.
* The surprising results of extreme crease and bend testing on printed silver conductors.
πŸ“‹ **Clip Abstract** This clip details the mechanical design and rigorous reliability testing of printed electronic leads on flexible TPU substrates. It reveals that through careful design and lamination, these systems can withstand hundreds of bend cycles and extreme creasing, proving their viability for rugged applications.
πŸ”— Link in comments πŸ‘‡

#PrintedElectronics, #TPUsubstrate, #SerpentineStructures, #MultiLayerLamination, #MedicalDevices, #WearableElectronics

00:12:36 - 00:14:45

Can you use printed electronics with painless microneedles to detect stress and infection biomarkers directly from your skin?

Can you use printed electronics with painless microneedles to detect stress and infection biomarkers directly from your skin?

This work moves beyond electrophysiology to biochemical sensing by sampling interstitial fluid (ISF), the fluid found in the spaces around cells. Using an array of painless microneedles that barely penetrate the skin, the patch can access this ISF, which is a rich source of biomarkers for monitoring conditions like stress (via cortisol) or physical exertion (via lactate) without drawing blood. This approach opens the door to continuous, minimally invasive monitoring of the body's biochemistry.

The device architecture is a prime example of flexible hybrid electronics, integrating several key components into a single patch. It combines the disposable microneedle array with all-printed electrochemical sensor cells. This sensor portion is connected to a reusable electronics module containing a miniaturized, lab-on-a-chip potentiostat from Analog Devices, which performs the complex electrochemical analysis directly on the body.

The platform supports multiple sensing technologies. While the lactate sensor is a relatively straightforward electrochemical sensor, the cortisol sensor represents a more advanced approach. It is a bio-recognition sensor that uses an aptamerβ€”a single-stranded DNA or RNA moleculeβ€”that specifically binds to cortisol. This binding event triggers a measurable change in electrical current, allowing for highly specific and sensitive detection of the target biomarker.

In this short video, you can learn:
* How painless microneedles can sample biomarker-rich interstitial fluid from below the skin.
* The flexible hybrid electronics architecture that integrates microneedles, printed sensors, and advanced silicon ICs.
* The use of aptamers as bio-recognition elements for creating highly specific printed sensors for molecules like cortisol.
πŸ“‹ **Clip Abstract** This clip explores a cutting-edge application of flexible electronics: a patch that uses painless microneedles to sample interstitial fluid for biochemical analysis. It details the system's architecture and the development of printed electrochemical sensors for biomarkers like lactate and cortisol, including an advanced aptamer-based sensor.
πŸ”— Link in comments πŸ‘‡

#PainlessMicroneedles, #FlexibleHybridElectronics, #PrintedElectrochemicalSensors, #AptamerSensors, #WearableElectronics, #BiomedicalSensing

More Snippets
CONTACT US

KGH Concepts GmbH

Mergenthalerallee 73-75, 65760, Eschborn

+49 17661704139

venessa@techblick.com

TechBlick is owned and operated by KGH Concepts GmbH

Registration number HRB 121362

VAT number: DE 337022439

  • LinkedIn
  • YouTube

Sign up for our newsletter to receive updates on our latest speakers and events AND to receive analyst-written summaries of the key talks and happenings in our events.

Thanks for submitting!

© 2026 by KGH Concepts GmbH

bottom of page