Mark Melnykowycz | IDUN Technologies: Can in-ear electrodes match scalp EEG signal strength while rejecting the motion artifacts that plague forehead recordings?
13:05 - 14:47
Other snippets from this talk
Summary of the clip:
Can in-ear electrodes match scalp EEG signal strength while rejecting the motion artifacts that plague forehead recordings?
A research student, Swati Landecker, evaluated in-ear versus forehead EEG using conductive fabrics around a foam-core earpiece and different ear-canal configurations. In an eyes-open/eyes-closed experiment, forehead and ear systems showed the same peak and the same increase in ELF activity. That validated that the ear locations were recording the same type of brain activity as the forehead.
The comparison also quantified signal quality. Motion artifacts acquired at the forehead were much greater than those at the ear, so from a signal-processing standpoint it should be relatively easier to clean up ear signals than scalp signals. This addresses the motion-artifact burden associated with forehead electrode locations.
When both electrode types produced very similar good data, the signal strengths were also very similar. That result indicates that algorithms developed for the ear can be made comparable to the gold standard. For in-ear EEG, the implication is that ear electrodes can combine validated brain-activity recording with lower motion-artifact susceptibility than forehead electrodes.
In this short video, you can learn:
* Eyes-open/eyes-closed testing produced the same ELF-activity peak at ear and forehead locations, validating that both recorded the same brain activity.
* Forehead motion artifacts were much greater than ear artifacts, making ear signals relatively easier to clean up in signal processing.
* With similarly good data from both electrode types, signal strengths were very similar, supporting ear algorithms comparable to the gold standard.
📋 **Clip Abstract** In-ear and forehead EEG were compared using conductive fabrics around a foam-core earpiece across ear-canal configurations. Eyes-open/eyes-closed testing showed matching ELF-activity peaks, much lower motion artifacts at the ear, and similar signal strengths when both electrode types produced good data.
About the speaker:
* Speaker: Mark Melnykowycz
* Company: IDUN Technologies
* Event: Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
* Location: Online
Join TechBlick - for the leading global event on wearable electronics
https://www.techblick.com/
#InEarEEG, #ForeheadEEGComparison, #MotionArtifactRejection, #ConductiveFabricFoamCore, #BrainComputerInterfaces, #WearableEEG
This is a highlight of the presentation:
Ubiquitous Brain Computer Interfaces Based on Ear EEG Electrodes
More Highlights from the same talk.
11:41 - 12:53
Why do customized hard-electrode earpieces fail to scale, and what modular electrode architecture replaces them?
Why do customized hard-electrode earpieces fail to scale, and what modular electrode architecture replaces them?
Literature shows strong ear EEG results, including automatic sleep staging and comparisons between ear EEG and scalp EEG. The recurring design difference is that many systems rely on highly customized earpieces with hard electrode materials. For massive market scaling, that customization becomes a problem: the device must be adaptable and not fitted to each person's ear-canal shape.
The electrode design started from the ground up for the ear. Early work used compliant electrodes on foam and explored customized electrodes made with 3D-printed silicone and thermoplastic polyurethane. That path led to a modular conductive ear tip combined with an earpiece, creating a mating that can be transferred to different industry projects rather than tied to one individual ear-canal geometry.
The resulting modular architecture targets transferability: the conductive ear tip and earpiece form a mating that can move into true wireless in-ear EEG designs and other industry projects. Validation began using established methods, framing the approach as a scalable alternative to hard-electrode, customized earpieces. The emphasis is adaptability across ear-canal shapes while preserving ear EEG measurement capability demonstrated in prior literature.
In this short video, you can learn:
* Ear EEG has been shown in literature to support automatic sleep staging and comparison with scalp EEG.
* Many existing ear-EEG designs use customized earpieces with hard electrode materials, which conflicts with massive market scaling.
* A modular conductive ear tip with an earpiece creates a transferable mating for true wireless in-ear EEG and other industry projects.
📋 **Clip Abstract** Ear EEG literature supports automatic sleep staging and direct comparison with scalp EEG, but many designs depend on customized earpieces using hard electrode materials. The presented approach moves from compliant foam electrodes and 3D-printed silicone or thermoplastic polyurethane toward a modular conductive ear tip plus earpiece, creating a transferable mating for true wireless in-ear EEG and other industry projects.
About the speaker:
* Speaker: Mark Melnykowycz
* Company: IDUN Technologies
* Event: Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
* Location: Online
Join TechBlick - for the leading global event on wearable electronics
https://www.techblick.com/
#EarEEG, #AutomaticSleepStaging, #CompliantFoamElectrodes, #ModularConductiveEarTip, #WearableSensors, #BrainComputerInterfaces
20:04 - 21:58
Should BCI firms build their own device, or supply Lego-like blocks to existing supply chains?
Should BCI firms build their own device, or supply Lego-like blocks to existing supply chains?
Large manufacturers said that unless a brain-computer interface supplier can provide Lego blocks for integration into existing supply chains, the product is worthless to them. The pathway for every BCI company is therefore not to create its own device and build a market around it, but to integrate with existing customer needs. Solving sleep disorders for Takeda or drowsiness for airline pilots can have larger market impact than an owned device.
Mass-market availability is targeted at three to five years. Before then, the business model and the neuro markers under development must be validated, and the supply chain must be built up. The device is moving from a relatively large neck-box form factor toward a true wireless design, a transition that precedes broader scaling.
Development is miniaturizing the biopotential amplifier, improving the modularity of the electrode system, and combining it with a system-on-a-chip for audio. The work examines how to interface with chips from Qualcomm and build the hardware profile. Once that exists, scaling becomes easier because it already works within products in that supply chain.
In this short video, you can learn:
* Manufacturers said a BCI product is worthless unless it can provide Lego-like blocks that integrate into their supply chains.
* The recommended pathway is to solve existing customer needs, such as Takeda sleep disorders or airline-pilot drowsiness, rather than build an owned device market.
* The three-to-five-year mass-market plan requires validated neuro markers, a built-out supply chain, a miniaturized biopotential amplifier, modular electrodes and audio system-on-a-chip integration with Qualcomm-type chips.
📋 **Clip Abstract** BCI commercialization should supply Lego-like building blocks that integrate into existing supply chains and solve customer-specific problems, rather than sell a standalone device. The mass-market route targets three to five years, combining neuro-marker validation and supply-chain buildout with a true-wireless design that miniaturizes the biopotential amplifier, modularizes electrodes and uses an audio system-on-a-chip interfacing with Qualcomm chips.
About the speaker:
* Speaker: Mark Melnykowycz
* Company: IDUN Technologies
* Event: Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
* Location: Online
Join TechBlick - for the leading global event on wearable electronics
https://www.techblick.com/
#BiopotentialAmplifier, #ModularElectrodeSystem, #AudioSystemOnAChip, #NeuroMarkerValidation, #BrainComputerInterfaces, #WearableSensors
About this talk
→ Ubiquitous Brain Computer Interfaces Based on Ear EEG Electrodes · Mark Melnykowycz · Wearable Sensors & Continuous Vital Signs Monitoring 2021