Peter Pasmans | Eternal Sun: How can inline module tests be correlated to stabilized power for nameplate rating?
14:51 - 16:09
Other snippets from this talk
Summary of the clip:
How can inline module tests be correlated to stabilized power for nameplate rating?
At end of line, modules are pre-conditioned with simple light to wake the devices before testing. This can be done in open-circuit conditions or with modules connected, and it takes a timescale of minutes. Every module then receives inline testing within the time available in the product cycle.
A sample of these modules is tested offline following standards, with full settling and MPP tracking, to determine a stabilized power. The amount sampled depends on the statistics required. The inline and offline results are then correlated. If there is a good correlation, inline results can be translated to stabilized power.
That translation can support the nameplate rating. If the correlation is not good, the method and statistics need to be improved. Eventually this leads to a nameplate rating, which can then be externally validated following the standards described earlier. So the inline/offline link is central.
In this short video, you can learn:
* Pre-conditioning modules with simple light for a timescale of minutes wakes devices before inline testing.
* Offline testing uses full settling and MPP tracking to determine stabilized power for sampled modules.
* Good correlation between inline and offline results allows inline results to be translated to stabilized power and nameplate rating.
📋 **Clip Abstract** End-of-line modules can be pre-conditioned with simple light for minutes, then tested inline within the product-cycle time. Sampled offline tests with full settling and MPP tracking establish stabilized power; correlation between inline and offline results supports translation to nameplate rating, or indicates the method and statistics need improvement.
About the speaker:
* Speaker: Peter Pasmans
* Company: Eternal Sun
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin
Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect
Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect
#InlineModuleTesting, #MPPTracking, #StabilizedPower, #NameplateRating, #PerovskitePV, #PVStabilityTesting
This is a highlight of the presentation:
Using steady-state LED simulation to enhance performance & stability testing for commercial perovskite PV
21 and 22 OCT 2026
Estrel, Berlin
Organised By:
More Highlights from the same talk.
01:43 - 03:32
Why does a perovskite sweep show massive hysteresis, and how can 10-second production cycles handle minutes-long steady-state measurements?
Why does a perovskite sweep show massive hysteresis, and how can 10-second production cycles handle minutes-long steady-state measurements?
Perovskite devices are not standard silicon devices: their measured state depends on the history of light and bias, and the material stack affects meta-stability. That is why MPP tracking is used, and why preconditioning matters. Understanding the light and bias history is therefore more important than with silicon, and MPP tracking only partly addresses the issue.
Hysteresis is linked to meta-stability and ion movement. At typical silicon sweep timescales, a perovskite sweep shows massive hysteresis. One route is faster timescales, effectively freezing the ions so hysteresis disappears; the other is slower, more steady-state measurement. Both are possible, but they represent different measurement regimes for the device.
The production challenge is the gap between steady-state sweep times and production cycles. More steady-state measurements need times on the order of minutes, while production cycles are typically on the order of 10 seconds. That gap has to be addressed. Measurement conditions also strongly affect the measured device state, as they do for meta-stability.
In this short video, you can learn:
* Perovskite measurements depend on light and bias history, so MPP tracking and preconditioning are needed.
* Typical silicon-timescale sweeps show massive hysteresis; faster sweeps freeze ions and slower sweeps approach steady state.
* Steady-state sweeps can require minutes, while production cycles are about 10 seconds, leaving a gap to address.
📋 **Clip Abstract** The talk explains why perovskite devices require MPP tracking and preconditioning because light and bias history plus material stack affect meta-stability. It contrasts fast sweeps that freeze ions with slow steady-state measurements needing minutes, against production cycles of about 10 seconds.
About the speaker:
* Speaker: Peter Pasmans
* Company: Eternal Sun
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin
Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect
Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect
#PerovskiteHysteresis, #MPPTracking, #IonMovement, #SteadyStateSweep, #PerovskitePV, #SolarCellTesting
11:05 - 11:54
How fast and accurately can LED-based tandem EQE match a monochromator reference?
How fast and accurately can LED-based tandem EQE match a monochromator reference?
Switching LEDs on and off enables tandem EQE measurement within 500 milliseconds or faster, producing a quasi-EQE without a monochromator. The resulting high-accuracy EQE curve shows less than 0.3% deviation in IEC when compared with a monochromator reference, according to the study with Vernon Eze. This links speed to reference-level accuracy rather than treating LED simulation as only qualitative.
The same EQE curve can tune the spectrum. Some bands allow spectral tuning while retaining an A+ rating, but the tuning changes whether the top cell or the bottom cell receives more light. Matching that split is therefore important. Tandem auto-calibration addresses it directly, with matching to less than 0.5% or even close to 0.1% when tuned to the high end.
High-speed LED switching supports both quasi-EQE acquisition and spectral adjustment in one workflow. Because the top and bottom cell light split must be matched, auto-calibration becomes a measurement and tuning lever, not just a setting. The reported deviation and matching figures quantify how closely the LED approach tracks the monochromator reference and the intended tandem spectrum.
In this short video, you can learn:
* LED on/off tandem EQE can be measured within 500 milliseconds or faster and still stay below 0.3% IEC deviation from a monochromator reference.
* Spectral tuning within allowed bands can preserve an A+ rating, but it shifts light between the top and bottom cells, so the split must be matched.
* Tandem auto-calibration can match the intended spectrum to less than 0.5% or close to 0.1% when tuned to the high end.
📋 **Clip Abstract** LED switching enables fast tandem EQE measurement within 500 milliseconds or faster, with less than 0.3% IEC deviation versus a monochromator reference. The same EQE curve supports spectral tuning and tandem auto-calibration, matching top/bottom cell light splits to less than 0.5% or close to 0.1% at the high end.
About the speaker:
* Speaker: Peter Pasmans
* Company: Eternal Sun
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin
Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect
Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect
#TandemEQE, #LEDSimulation, #TandemAutoCalibration, #SpectralTuning, #PerovskitePV, #TandemSolarCells
07:28 - 09:35
Why does a 200-hour 85°C test represent only one year outdoors for perovskite modules?
Why does a 200-hour 85°C test represent only one year outdoors for perovskite modules?
The draft 61215-1-6 standard, led by Frank Schoustra of Oxford PV and Bui Duong of MicroQuantia, began with a May meeting and aims for a committee draft at the next Work Group 2 meeting. It covers single junction, two-terminal tandem, four-terminal two-cable and four-terminal four-cable product configurations, plus stabilization and a light-and-elevated-temperature protocol.
The current light-and-elevated-temperature draft proposes 200 hours at 85°C. Assuming outdoor temperatures near 65°C over a 30-year lifetime, modules receive 35,000 to 70,000 kilowatt hours per square meter in most climates. With a material-dependent acceleration factor of three and a half times, demonstrating 30 years at one sun would require 10,000 to 20,000 hours, so 200 hours represents about one year outdoors.
Because 200 hours is still a relatively short stability test, the talk notes that once devices become more stable, further advanced test protocols should be developed. ISIS protocols already exist, and they test different cycles. The discussion also stresses that stability testing is important for demonstrating perovskite device performance, while the current test time remains relatively short.
In this short video, you can learn:
* The 61215-1-6 draft covers single-junction, two-terminal tandem, four-terminal two-cable and four-terminal four-cable product configurations, plus stabilization.
* A 200-hour test at 85°C is proposed, but a 30-year outdoor lifetime may require 10,000 to 20,000 hours at one sun using a 3.5× acceleration factor.
* ISIS protocols with different cycles are identified as advanced testing needed once devices become more stable.
📋 **Clip Abstract** The clip explains the draft 61215-1-6 perovskite PV standard, including product configurations and a proposed 200-hour 85°C light-and-elevated-temperature test. It compares that test with 30-year outdoor exposure calculations and points to ISIS cycle protocols for more advanced stability testing.
About the speaker:
* Speaker: Peter Pasmans
* Company: Eternal Sun
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin
Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect
Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect
#Draft61215Standard, #LightElevatedTemperatureTest, #TwoTerminalTandem, #AccelerationFactor, #PerovskitePV, #TandemSolarCells
About this talk