top of page

Roni Yehuda

SolarEdge

* All members of the platform can watch the entire presentation.

 

Please register to become a member.

Roni Yehuda | SolarEdge: Which perovskite tandem mismatches force different optimizer wiring for 2T versus 4T?

03:34 - 04:53

Other snippets from this talk

Summary of the clip:

Which perovskite tandem mismatches force different optimizer wiring for 2T versus 4T?

Tandems are efficient, but the clip says they are also more exposed to mismatch: solar-spectrum variation, temperature, distinct layer-property effects, bifacial albedo, uneven degradation across modules and sub-layers, and manufacturing variability. These are the mismatch categories raised before comparing how 2T and 4T modules connect to optimizers.

For 2T, the transcript states a single-input optimizer is used, described as most of the off-the-shelf products and the same connection as data silicon modules. For 4T, a dual-input optimizer is used: each layer connects to another input but on the same optimizer, and the output goes into one string to the inverter.

The string demonstration uses only three modules, presented as an illustration rather than a full array. The 2T string is wired as today with one input. The 4T approach keeps each layer on a separate input of the same dual-input optimizer while combining output into one string to the inverter.

In this short video, you can learn:
* 2T modules connect to a single-input optimizer, the same as the data silicon modules described.
* 4T modules connect each layer to a separate input on a dual-input optimizer.
* The 4T optimizer output goes into one string to the inverter.

📋 **Clip Abstract** Tandems are efficient but exposed to solar-spectrum, temperature, bifacial-albedo, degradation and manufacturing mismatches. The 2T configuration uses a single-input optimizer, while 4T uses a dual-input optimizer with each layer on a separate input and one output string to the inverter.

About the speaker:
* Speaker: Roni Yehuda
* Company: SolarEdge
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#SingleInputOptimizer, #DualInputOptimizer, #BifacialAlbedo, #ManufacturingVariability, #TandemSolar, #Photovoltaics

This is a highlight of the presentation:

Perovskite tandem delivers. Mismatch steals. MLPE saves the gains.

​

​

21 and 22 OCT 2026

Estrel, Berlin

Organised By:

​

​

More Highlights from the same talk.

05:25 - 06:41

Can a 12-year, no-shading simulation isolate optimizer gains from manufacturing variability and uneven aging in 2T and 4T perovskite tandem modules?

Can a 12-year, no-shading simulation isolate optimizer gains from manufacturing variability and uneven aging in 2T and 4T perovskite tandem modules?

The simulation compared power optimizers with a string inverter for perovskite tandem modules in both 2T and 4T configurations. It covered a 12-year period, with the presenter noting the run was very large and only main assumptions were highlighted. The scope was deliberately set to optimizer versus string-inverter behavior for tandem modules, before the mismatch assumptions were applied.

To isolate optimizer effects from shading, the simulation eliminated shading entirely. The talk explicitly set aside the earlier 10% and 4% shading orientations, and sometimes more, because the goal was to observe the real effect of optimizers on perovskite modules. This no-shading assumption is central to separating mismatch-driven gains from shading-driven gains.

For mismatch, the simulation considered manufacturing variability and uneven aging between modules. Those two sources define the mismatch under test in the 12-year, no-shading comparison of power optimizers versus string inverter with 2T and 4T perovskite tandem modules. The assumptions frame how optimizer gains are attributed to tandem mismatch rather than shading.

In this short video, you can learn:
* The simulation compared power optimizers against a string inverter using 2T and 4T perovskite tandem modules over a 12-year period.
* Shading was eliminated, including the earlier 10% and 4% and sometimes more shading orientations, to isolate the real optimizer effect on perovskite modules.
* Mismatch was modeled as manufacturing variability plus uneven aging between modules.

📋 **Clip Abstract** A 12-year simulation compared power optimizers with a string inverter for 2T and 4T perovskite tandem modules. By removing shading, including the earlier 10% and 4% and sometimes more orientations, and modeling mismatch as manufacturing variability plus uneven aging, it isolated optimizer effects from shading effects.

About the speaker:
* Speaker: Roni Yehuda
* Company: SolarEdge
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#PerovskiteTandem, #2T4TModules, #PowerOptimizerSimulation, #ManufacturingVariability, #Photovoltaics, #PVSystems

09:11 - 10:56

How much extra annual energy do optimizers recover from tandem mismatch alone, and what is the conclusion?

How much extra annual energy do optimizers recover from tandem mismatch alone, and what is the conclusion?

In a no-shading simulation, the 2T configuration at medium variability showed 5.19% extra annual energy with optimizers versus a string inverter for the same system, size and location. The 10% and 4% figures sit on top depending on site irradiation and direction. The comparison is like-for-like: same modules, same system size, same location.

The simulation can be used with many different inputs, producing a wide range of data rather than a single case. The key takeaway is not to stop at advanced modules; unlock system value with power optimizers. The claim is that the ultimate partner for Percio technology is MLP, specifically optimizers, to mitigate today’s mismatch risks.

After the simulation, the effort is moving toward field testing. The broader takeaway is to pair advanced modules with power optimizers, because the simulation positions optimizers as the ultimate partner for Percio technology and as a way to mitigate mismatch risks.

In this short video, you can learn:
* Medium variability on the 2T configuration yields 5.19% extra annual energy with optimizers versus a string inverter for the same system, size and location.
* The 10% and 4% values sit on top depending on site irradiation and direction, without shading.
* The conclusion is not to stop at advanced modules: power optimizers are positioned as the partner for Percio technology to mitigate mismatch risks, and field testing follows the simulation.

📋 **Clip Abstract** A no-shading simulation shows 5.19% extra annual energy for the 2T configuration at medium variability when optimizers replace string-inverter connection for the same system, size and location. The conclusion is to pair advanced modules with power optimizers to mitigate mismatch risks, with field testing following the simulation.

About the speaker:
* Speaker: Roni Yehuda
* Company: SolarEdge
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#2TConfiguration, #PowerOptimizers, #MismatchMitigation, #AnnualEnergyGain, #PerovskiteTandem, #SolarPhotovoltaics

07:08 - 09:00

How were low, medium and high perovskite variability parameterized for the 12-year tandem simulation?

How were low, medium and high perovskite variability parameterized for the 12-year tandem simulation?

The simulation fixed module-to-module temperature standard deviation at two degrees and irradiance at 1%, then calculated annual energy weighted. It separated module-to-module manufacturing variability from age variability at year 12. Aging variability excluded hotspot, reverse bias, shading and soiling. Batch-to-batch offsite variability used three batches per string, mixed in the same string, matching current silicon practice.

Data came from industry, field testing, lab testing, certifications, researchers and articles. The team divided perovskite variability into low, medium and high groups, each with its own numbers and different scaling. Silicon remained steady and familiar, with known numbers. The simulation then compared power optimizers against a string inverter using the same perovskite tandem modules in a 2T configuration.

The result was calculated annual energy weighted, with the outcome promised for later. Each perovskite variability group received its own numbers with different scaling, while silicon used steady, familiar numbers. The comparison kept the same perovskite tandem modules, 2T, and tested power optimizers versus a string inverter.

In this short video, you can learn:
* Temperature standard deviation was two degrees and irradiance was 1%, with annual energy weighted.
* Perovskite variability was split into low, medium and high groups, each with separate numbers and scaling.
* Three batches per string were mixed to model batch-to-batch offsite variability, as with current silicon.

📋 **Clip Abstract** The simulation set module-to-module temperature standard deviation at two degrees and irradiance at 1%, then calculated annual energy weighted. It divided perovskite variability into low, medium and high groups with separate scaling and compared power optimizers against a string inverter using identical perovskite tandem modules in 2T.

About the speaker:
* Speaker: Roni Yehuda
* Company: SolarEdge
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#ModuleToModuleVariability, #BatchToBatchMixing, #AnnualEnergyWeighted, #StringInverterComparison, #PerovskiteTandem, #SolarPhotovoltaics


About this talk

→ Perovskite tandem delivers. Mismatch steals. MLPE saves the gains. · Roni Yehuda · Perovskite Connect 2026

More Snippets
CONTACT US

KGH Concepts GmbH

Mergenthalerallee 73-75, 65760, Eschborn

+49 17661704139

admin@techblick.com

TechBlick is owned and operated by KGH Concepts GmbH

Registration number HRB 121362

VAT number: DE 337022439

  • LinkedIn
  • YouTube

Sign up for our newsletter to receive updates on our latest speakers and events AND to receive analyst-written summaries of the key talks and happenings in our events.

Thanks for submitting!

© 2026 by KGH Concepts GmbH

bottom of page