Adam Lorenz | CubicPV: Does a 2% Jsc drop over three months prove perovskite degradation — or just seasonal spectral shift?

05:22 - 07:52

Other snippets from this talk

Summary of the clip:

Does a 2% Jsc drop over three months prove perovskite degradation — or just seasonal spectral shift?

Field data from a 400 mm module on a Massachusetts rooftop is plotted using daily efficiency — a metric developed by PAX in Colorado and Sandia National Labs in New Mexico. You add up the kilowatt hours generated across the day, measure irradiance with a pyranometer, and average the day's performance, so odd morning behaviour shows up. The colour bar separates sunny from cloudy days; the lower trace is peak module temperature.

At a Southeast Asian site module temperatures exceed 70 °C, and a full year of that performance was demonstrated with less than 1% degradation. The acceleration factor for perovskites between a very hot climate and a more modest one — or Berlin — can be more than 10X. So when someone quotes a degradation rate, ask which environment it corresponds to.

Jsc typically doesn't change much for perovskites, yet over three months this module showed a 2% drop — entirely due to spectral change, with fewer photons in the portion of the spectrum the perovskite absorbs. The AM1.5 spectrum shifts significantly between January and July: counting photons hitting perovskite versus silicon, physics alone gives a five to 10% current change, and summer to fall yields about 2% in Jsc.

In this short video, you can learn:
* A year at module temperatures above 70 °C in Southeast Asia produced less than 1% degradation, but the perovskite acceleration factor versus a modest climate such as Berlin can exceed 10X.
* Daily efficiency, used by PAX and Sandia, integrates the whole day's kWh against pyranometer irradiance so that anomalous morning behaviour is captured.
* The 2% Jsc drop over three months traced entirely to AM1.5 spectral shift, not to cell degradation.

📋 **Clip Abstract** Field data from a 400 mm rooftop module in Massachusetts shows how daily efficiency, peak module temperature and irradiance separate sunny from cloudy days. A Southeast Asian site above 70 °C delivered under 1% degradation over a year, while a 2% Jsc loss over three months traced entirely to seasonal AM1.5 spectral shift.

About the speaker:
* Speaker: Adam Lorenz
* Company: CubicPV
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#DailyEfficiencyMetric, #AM15SpectralShift, #JscSpectralLoss, #ModuleTemperatureAcceleration, #PerovskiteStability, #EnergyYieldAnalysis

This is a highlight of the presentation:

Establishing Perovskite Bankability with Accelerated Testing and Energy Yield Analysis

​

​

21 and 22 OCT 2026

Estrel, Berlin

Organised By:

​

​

More Highlights from the same talk.

09:38 - 11:40

How can indoor light soaking, five-sun UV, and independent electrical bias reveal perovskite degradation?

How can indoor light soaking, five-sun UV, and independent electrical bias reveal perovskite degradation?

Indoor testing uses a bank of PV bake ovens—light-soaking chambers combining one-sun illumination with heat. Aggressive runs sit at 90 °C; variable-temperature testing spans up to 105 °C and back to room temperature. Best devices retain 95% of power after 1,000 hours at 90 °C, which translates to 10 or 20 years depending on climate.

The chambers control illumination for day/night cycles and white light; because the platform is a four-terminal tandem, spectral match matters less when studying only the perovskite. A UV component reaches up to five suns. The stage now uses Peltier temperature cycling instead of a pad heater, enabling up-and-down temperature control.

Custom measurement boards monitor up to 216 independent channels. With 50 mm coupons, 36 samples each carrying six pixels can be tracked independently. Some pixels are held at maximum power point, some at open-circuit voltage, and some at short circuit, revealing how electrical bias interacts with degradation conditions.

In this short video, you can learn:
* Best devices retained 95% of power after 1,000 hours at 90 °C, translating to 10–20 years depending on climate.
* Testing can apply one-sun white light, day/night cycles, up to five suns of UV, and Peltier-driven temperature cycling from room temperature to 105 °C.
* Custom boards track up to 216 channels across 50 mm coupons, holding pixels at maximum power point, open-circuit voltage, or short circuit to study bias-degradation interactions.

📋 **Clip Abstract** Indoor light-soaking chambers combine one-sun illumination, 90–105 °C heat, day/night cycling, up to five-sun UV, and Peltier temperature control. Custom boards monitor 216 independent channels on 50 mm coupons, comparing maximum-power, open-circuit, and short-circuit biases to link electrical stress with perovskite degradation.

About the speaker:
* Speaker: Adam Lorenz
* Company: CubicPV
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#PerovskiteLightSoaking, #PeltierTemperatureCycling, #FourTerminalTandem, #MaximumPowerPointBias, #PerovskiteSolarCells, #PVBankability

15:00 - 17:08

Why is slot-die coated perovskite on 0.2 mm glass suited to lightweight space use and 4-terminal tandems?

Why is slot-die coated perovskite on 0.2 mm glass suited to lightweight space use and 4-terminal tandems?

The processing steps used for deposition on thick glass for terrestrial applications have been translated to 0.2 mm glass for space. The same slot-die coating process is used for the perovskite layer and other steps. The result is a 20% perovskite-only device with a lightweight stack below one kilogram per square metre.

Space adds new stressors such as extreme thermal cycling. In lower orbit, cycles occur on a 90-minute interval, translating to 20,000 or even 40,000 thermal cycles. That is a different level of stress, and may require examining mineralization context and related factors.

A four-terminal architecture was chosen because it is easier and simpler. It removes design constraints around matching current density or coating textured surfaces. Durability is king: the flexibility to deposit on glass with the chemistry of choice lets the work focus on durability rather than those constraints.

In this short video, you can learn:
* Slot-die coating on 0.2 mm glass has produced a 20% perovskite-only device below 1 kg/m².
* Lower-orbit thermal cycling every 90 minutes can mean 20,000 to 40,000 cycles.
* The four-terminal route was selected for simplicity and freedom from current-density matching and textured-surface coating constraints.

📋 **Clip Abstract** The talk describes translating terrestrial thick-glass deposition steps to 0.2 mm glass for space, using the same slot-die coating for perovskite and other layers to reach a 20% perovskite-only device below 1 kg/m². It also flags 90-minute lower-orbit thermal cycles translating to 20,000–40,000 cycles and explains why a four-terminal architecture was chosen for simplicity, freedom from current-density matching and textured-surface coating, and durability focus.

About the speaker:
* Speaker: Adam Lorenz
* Company: CubicPV
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#SlotDieCoating, #ThinGlassPV, #FourTerminalArchitecture, #ThermalCycling, #PerovskitePhotovoltaics, #SolarCellTesting

11:40 - 14:06

How can accelerated light-dark cycling identify ion migration issues and drive perovskite stack improvements?

How can accelerated light-dark cycling identify ion migration issues and drive perovskite stack improvements?

The test compares two stacks over 120 hours of degradation, with a zoom on 100–105 hours. Instead of 12 hours on and 12 hours off, light cycling is accelerated at 90°C: a couple of hours at sunlight, then dark annealing or dark soaking for about half an hour, equivalent to a full night at lower temperature. Every light-off event produces a voltage drop as ions move inside the material.

A stack change was made to mitigate that ion-driven response. Looking only at the top line of the two stacks shows very little difference, but more sophisticated analysis reveals behavior inside the device. Data gaps every 15 cycles mark temperature drops and room-temperature re-measurement, where voltage drops significantly from charge barriers building up at the interface—effects that can influence daily outdoor performance.

Outdoor module data use time of day on the x-axis: as modules spend longer in the field, temperatures change and a daily wake-up performance appears. Implementing the changed stack in the field maintains higher voltage throughout the day, including early morning. With irradiance on the x-axis, the same stacks show higher voltage and higher fill factor under lower irradiance over a few months.

In this short video, you can learn:
* Accelerated light-dark cycling at 90°C uses short dark soaking to emulate a full night and exposes ion-driven voltage drops when light is switched off.
* A stack modification that looks nearly identical in top-line degradation can be distinguished through room-temperature re-measurement every 15 cycles and analysis of interface charge barriers.
* Field modules with the changed stack sustain higher voltage through the day, including early morning, and higher voltage and fill factor at lower irradiance over a few months.

📋 **Clip Abstract** Accelerated light-dark cycling at 90°C compares two stacks over 120 hours and uses room-temperature re-measurement every 15 cycles to expose ion migration and interface charge-barrier effects hidden in top-line degradation. The stack change mitigating these effects is linked to outdoor module data with higher daytime voltage and higher voltage and fill factor at lower irradiance over a few months.

About the speaker:
* Speaker: Adam Lorenz
* Company: CubicPV
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#LightDarkCycling, #IonMigration, #ChargeBarrierAnalysis, #EnergyYieldAnalysis, #PerovskiteSolarCells, #PerovskitePhotovoltaics

More Snippets
CONTACT US

KGH Concepts GmbH

Mergenthalerallee 73-75, 65760, Eschborn

+49 17661704139

admin@techblick.com

TechBlick is owned and operated by KGH Concepts GmbH

Registration number HRB 121362

VAT number: DE 337022439

  • LinkedIn
  • YouTube

Sign up for our newsletter to receive updates on our latest speakers and events AND to receive analyst-written summaries of the key talks and happenings in our events.

Thanks for submitting!

© 2026 by KGH Concepts GmbH

bottom of page