Azar Alizadeh | GE Healthcare: How does GE design multi-modal vital sign monitoring patches to achieve clinical-grade fidelity in a disposable form factor?

11:22 - 13:34

Other snippets from this talk

Summary of the clip:

How does GE design multi-modal vital sign monitoring patches to achieve clinical-grade fidelity in a disposable form factor?

The more complex generation integrates a three-lead ECG, dual respiration measurements, reflective PPG and temperature in one patch. An electronics unit controls all patch functions with Bluetooth or other wireless capabilities, accelerometry, temperature and onboard storage. Attention centers on electronics performance and optimized manufacturing matched to clinical counterparts, with head-to-head comparisons of signal quality and signal stability against clinical devices.

To turn these devices into single-use products, the manufacturing approach uses flexible hybrid electronics to be cost-effective and scalable. That requires a marriage of disparate manufacturing components and supply chains. The design and production are optimized so the patch's electronics can match clinical counterparts, while the flexible hybrid route supports disposable manufacturing rather than a reusable clinical device.

The miniaturized version removes the three-dimensional ECG, and its respiration modality also changes, but it aims to maintain the same type of clinical fidelity. Development is driven by the need based on operation, as noted in the talk. Both generations therefore trade functions and form factor while retaining careful electronics design and clinical-comparison validation.

In this short video, you can learn:
* The complex patch combines three-lead ECG, dual respiration, reflective PPG and temperature.
* Flexible hybrid electronics enable cost-effective scalable manufacturing for single-use patches.
* The miniaturized patch drops 3D ECG and changes respiration while targeting comparable clinical fidelity.

📋 **Clip Abstract** This clip examines two generations of disposable vital sign patches, focusing on a complex version with three-lead ECG, dual respiration, reflective PPG and temperature. It explains how flexible hybrid electronics, optimized electronics and head-to-head clinical comparisons support scalable single-use manufacturing while the miniaturized version changes modalities but targets clinical fidelity.

About the speaker:
* Speaker: Azar Alizadeh
* Company: GE Healthcare
* Event: Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
* Location: Online

Join TechBlick - for the leading global event on wearable electronics
https://www.techblick.com/

#FlexibleHybridElectronics, #ThreeLeadECG, #DualRespiration, #ReflectivePPG, #WearableSensors, #FlexibleElectronics

This is a highlight of the presentation:

Disposable, Adjustable Clinical Grade Vital Sign Monitoring Systems

Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021

​

13-14 October 2021

Online

Organised By:

TechBlick

​

More Highlights from the same talk.

15:15 - 17:42

Why must printed SpO2 sensors and main motherboards be placed separately on flexible vital sign monitoring patches?

Why must printed SpO2 sensors and main motherboards be placed separately on flexible vital sign monitoring patches?

The electronics unit is split into two separate components in the more 3D DCG version because the PPG, which measures parameters such as blood oxygenation, must sit below the clavicle for good reflective SpO2. The motherboard is instead placed close to the side of the ribs for comfort. Both are highly miniaturized and copper-flex based; the motherboard supports ECG, respiration and temperature, while the PPG module remains separate.

For printed wires, the work was done closely with DuPont and manufacturing supplier GM Nameplate. The approach is a multilayer print structure that allows shielding of the wires. The base substrate is PET, where multiple inks have been optimized. This device can be bent at a very sharp angle, important because the devices are adjustable for different body sizes.

The choice of dielectrics or laminations allows these devices to be compatible with high-voltage applications, in case defibrillation is one of the hospital requirements. The result is described as very high-performing, with low- and high-conductivity devices. The separate miniaturized modules and shielded printed wires support adjustable devices for different body sizes.

In this short video, you can learn:
* PPG must be below the clavicle for reflective SpO2, while the motherboard sits near the side of the ribs for comfort.
* A multilayer print structure on PET shields printed wires, enabling sharp bending and body-size adjustment.
* Dielectric and lamination choices make the devices compatible with high-voltage hospital defibrillation requirements.

📋 **Clip Abstract** The electronics unit is split into two highly miniaturized copper-flex components: a PPG module below the clavicle for reflective SpO2 and a motherboard near the side of the ribs for comfort that supports ECG, respiration and temperature. Printed wires use a multilayer structure on PET for shielding, sharp bending and adjustable body sizes, with dielectric and lamination choices compatible with high-voltage defibrillation requirements.

About the speaker:
* Speaker: Azar Alizadeh
* Company: GE Healthcare
* Event: Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
* Location: Online

Join TechBlick - for the leading global event on wearable electronics
https://www.techblick.com/

#ReflectiveSpO2, #MultilayerPrintShielding, #PETSubstrate, #CopperFlexModules, #WearableSensors, #FlexibleElectronics

22:57 - 24:31

What supply chain architecture moves flexible hybrid wearables from laboratory prototypes into relevant manufacturing environments?

What supply chain architecture moves flexible hybrid wearables from laboratory prototypes into relevant manufacturing environments?

All design is performed in-house, and the initial breadboard demonstration is done by the team. Some printing capability exists at the research institute, but the deliberate approach is to work with manufacturing suppliers such as Nisha and GM Nameplate at prototyping scale. That fabrication occurs in the relevant manufacturing environment, with the stated goal of demonstrating that manufacturing can move from the lab to manufacturing.

At the end of the day, the motherboard is done in factories and shipped back, the same as the printed devices, which remain in the prototype stage but are made outside. The team performs a lot of testing, additional quality control and revalidations itself. This division separates external factory fabrication from internal validation.

On interconnect architecture, the response identifies single-layer interconnects rather than multi-layer ones. The materials answer begins with “largely” but is not completed in the clip, so no specific material can be attributed from this segment. The supply-chain discussion therefore links in-house design, external prototype fabrication and internal quality control as the transition path.

In this short video, you can learn:
* Design and breadboard demonstration are internal, while prototyping fabrication is deliberately delegated to manufacturing suppliers including Nisha and GM Nameplate in relevant factory environments.
* Motherboards are factory-built and shipped back, printed devices remain prototypes made outside, and testing, additional quality control and revalidations are performed internally.
* The interconnect response identifies single-layer interconnects, but the materials answer is cut off after “largely,” so no material is specified in this clip.

📋 **Clip Abstract** The clip describes an in-house design and breadboard path, with prototyping fabrication deliberately moved to manufacturing suppliers including Nisha and GM Nameplate in relevant factory environments. Motherboards are factory-built and shipped back while printed devices remain prototypes made outside; testing, QC and revalidations stay internal, and the interconnect response identifies single-layer structures before the materials answer is cut off.

About the speaker:
* Speaker: Azar Alizadeh
* Company: GE Healthcare
* Event: Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
* Location: Online

Join TechBlick - for the leading global event on wearable electronics
https://www.techblick.com/

#SingleLayerInterconnects, #PrototypeFabrication, #FactoryBuiltMotherboards, #QualityControlRevalidation, #WearableSensors, #FlexibleHybridElectronics

17:41 - 19:56

Why do 600 Hz heart-rate and 100 Hz PPG sampling cap a patch at 3.5 days, and what does cutting the rate buy?

Why do 600 Hz heart-rate and 100 Hz PPG sampling cap a patch at 3.5 days, and what does cutting the rate buy?

The patch is built from high-conductivity conductors that stay both bendable and stretchable over a very long period. The functional answer to fit is mechanical: the middle regions of the device stretch or compress the wiring so one unit adapts to different body sizes. A person with a thin body frame uses the same device as a larger wearer, removing the need for many different device sizes.

An Android app displays all of the parameters, and embedded algorithms convert the raw wave functions into clinically familiar metrics such as heart rate and respiration rate. Critically, the device supports continuous transmission at a very fast data rate for up to 3.5 days. That continuous link is what defines the usable wear window for subacute monitoring.

The sampling rates are stated plainly: heart rate at 600 Hz and photoplethysmography at 100 Hz. For subacute monitoring those rates are unnecessary, so transmission can be reduced and battery lifetime extended up to 1 week. The device tolerates showering, is comfortable to wear, and is being taken forward with AFRL colleagues for air medical transport.

In this short video, you can learn:
* Heart rate is sampled at 600 Hz and PPG at 100 Hz, sustaining continuous transmission for up to 3.5 days.
* Reducing the transmission rate for subacute monitoring extends battery lifetime up to 1 week.
* Stretch-and-compress regions in the middle of the wiring let a single device fit different body frames, and the work is now aimed with AFRL at air medical transport.

📋 **Clip Abstract** A stretchable, high-conductivity clinical patch that adjusts mechanically to different body frames and streams raw waveforms through an Android app into heart rate and respiration rate. Continuous transmission at 600 Hz heart rate and 100 Hz PPG runs 3.5 days, while lowering the rate for subacute monitoring reaches 1 week of battery life.

About the speaker:
* Speaker: Azar Alizadeh
* Company: GE Healthcare
* Event: Electronic Textiles, Wearable Sensors & Printed/Flexible Sensors 2021
* Location: Online

Join TechBlick - for the leading global event on wearable electronics
https://www.techblick.com/

#StretchableInterconnects, #PPGSamplingRate, #ContinuousVitalSignTransmission, #AirMedicalTransport, #WearableSensors, #FlexibleElectronics

More Snippets
CONTACT US

KGH Concepts GmbH

Mergenthalerallee 73-75, 65760, Eschborn

+49 17661704139

admin@techblick.com

TechBlick is owned and operated by KGH Concepts GmbH

Registration number HRB 121362

VAT number: DE 337022439

  • LinkedIn
  • YouTube

Sign up for our newsletter to receive updates on our latest speakers and events AND to receive analyst-written summaries of the key talks and happenings in our events.

Thanks for submitting!

© 2026 by KGH Concepts GmbH

bottom of page