Tobias Steinel | Instrument Systems GmbH: Why does MicroLED display uniformity fall apart at low gray levels, and how do we fix it?

04:55 - 06:15

Other snippets from this talk

Summary of the clip:

Why does MicroLED display uniformity fall apart at low gray levels, and how do we fix it?

Performing electro-luminescence testing on the fully assembled display panel leverages the already integrated driver backplane. This configuration allows testing software to directly address and adjust individual pixels. This systematic calibration process, commonly known as "demura", is essential for correcting spatial non-uniformities across the active display area.

A major challenge in MicroLED displays is that pixel uniformity drops precipitously at low gray levels and low luminance conditions. This instability distorts the display's gamma curve and degrades image quality in dark scenes, representing a key bottleneck for high-end consumer AR/VR displays.

To combat this, specialized optical systems must be optimized to measure extremely low light levels. By reliably capturing emission profiles down to 1 millicandela and below, these systems enable accurate low-luminance demura calibration, ensuring a flat gamma response across the entire operating range.

In this short video, you can learn:
* The role of active-matrix driver backplanes in performing pixel-level demura calibration
* Why MicroLED uniformity degrades at low gray levels and low candela outputs
* How sub-millicandela measurement capabilities enable high-quality display calibration

📋 **Clip Abstract** This clip explores the critical process of display-level demura calibration and the hurdles of maintaining MicroLED uniformity at ultra-low luminance. It details how measuring below 1 millicandela is required to stabilize the gamma curve and achieve seamless visual uniformity.

#DemuraCalibration, #LowGrayLevelUniformity, #SubMillicandelaMeasurement, #ActiveMatrixBackplane, #MicroLEDDisplays, #AugmentedRealityDisplays

This is a highlight of the presentation:

​

Printed Electronics Innovation Day 2024

Display Innovation Day 2024

​

TechBlick | Online Platform

Organised By:

TechBlick

​

More Highlights from the same talk.

05:37 - 07:01

How do you measure peak wavelength, power and polarization of every VCSEL emitter in an optical interconnect array?

How do you measure peak wavelength, power and polarization of every VCSEL emitter in an optical interconnect array?

The co-packaged optics setup starts with VCSEL arrays imaged by a camera system alongside a spectrometer — the standard configuration used across all production equipment. The camera captures the near-IR emitter array, locating each emitter and measuring its radiant power. Spectra are measured and peak wavelengths assigned to individual emitters, mapping the array. So position, power and peak wavelength are resolved per emitter.

Polarization measurement works like an RGB sensor, where different pixels receive light through different polarization filters. That lets the system measure polarization state per emitter. Polarization matters for in-coupling into optical connect devices and for slope efficiency. These capabilities are already solved, with machines in production for VCSEL arrays today, and the same systems can be used at the same time for micro-LEDs or any other light emitter in connect applications.

With position, radiant power, spectra, peak wavelength and polarization addressed, the discussion turns to speed. Why emphasize speed? The machines described are already in production for VCSEL arrays, and the platform can handle micro-LEDs or any other emitter for connect applications. Speed becomes the next topic raised in the talk, immediately after the solved measurement stack.

In this short video, you can learn:
* A camera system plus spectrometer images the near-IR emitter array, locating each emitter and measuring its radiant power.
* Spectra are measured and peak wavelengths are assigned to emitters, mapping the array.
* Polarization is measured like an RGB sensor with different polarizations at different pixels, which matters for in-coupling into optical connect devices and slope efficiency.

📋 **Clip Abstract** Camera-and-spectrometer systems image near-IR VCSEL arrays, resolving each emitter's position, radiant power, spectra, peak wavelength and polarization. These machines are already in production for VCSEL, with polarization important for in-coupling and slope efficiency, and can be used for micro-LEDs or any other light emitter for connect applications.

About the speaker:
* Speaker: Tobias Steinel
* Company: Instrument Systems
* Event: Eindhoven 2026
* Location: High Tech Campus, Eindhoven

#VCSELArrays, #PeakWavelengthMapping, #PolarizationMetrology, #RadiantPowerMapping, #CoPackagedOptics, #MicroLEDDisplays

10:57 - 12:42

Why do displays matched to the same D65 white point look pink to different observers?

Why do displays matched to the same D65 white point look pink to different observers?

The example compares LCD, OLED and Rec. 2020 spectra, including laser lines. The black reference is the D65 standard white. When the white point is calibrated to D65 and measured with different observers, each observer lands elsewhere in color space, even though the calibrated white point is the same. That sets up metamerism risk across technologies.

With OLED, micro-LED and quantum dots, multiple observers are more sensitive. Different spectra calibrated to the same D65 white point produce strong metamerism failure. The observers see mostly a pink shade, because the calibrated white point is not what they perceive. This was reproduced using a tablet and two smartphones, all calibrated closely to the same white point.

When those tablet and smartphone displays are viewed in a different color space, they lie apart from each other. That matches the visual result: the same nominal white point separates into different observed whites. The talk notes that the Apple 2026 color matching function was recently introduced. The same set of spectra comes from LCD, OLED, micro-LED, quantum dots and Rec. 2020 laser displays.

In this short video, you can learn:
* Calibrating LCD, OLED and Rec. 2020 displays to the same D65 white point still produces strong metamerism failure across different observers.
* The observers in the example see mostly a pink shade, and a tablet plus two smartphones calibrated closely to the same white point lie apart in a different color space.
* An Apple 2026 color matching function was recently introduced, according to the talk.

📋 **Clip Abstract** When LCD, OLED and Rec. 2020 spectra are calibrated to the same D65 white point, different observers end up somewhere else in color space, producing strong metamerism failure. The example shows a mostly pink shade, and a tablet plus two smartphones calibrated closely to the same white point lie apart in another color space, while an Apple 2026 color matching function has recently been introduced.

About the speaker:
* Speaker: Tobias Steinel
* Company: Instrument Systems
* Event: Eindhoven 2026
* Location: High Tech Campus, Eindhoven

#D65WhitePoint, #MetamerismFailure, #Rec2020Spectra, #ColorMatchingFunction, #OpticalMetrology, #DisplayColorScience

06:58 - 09:05

Why is microLED pixel compensation harder than OLED, and what must be measured per emitter?

Why is microLED pixel compensation harder than OLED, and what must be measured per emitter?

MicroLED arrays and optical connect devices contain millions of emitters — thousands in the optical connect case — and each single emitter can carry its own faults, cracks and defects, requiring individual treatment. Metrology therefore runs as a circle: measure, calibrate the image, analyze, pass-fail, then repeat many times until a very inhomogeneous starting display becomes homogeneous. The same holds for CPOs and optical connect arrays.

Why speed? Because these cycles become more numerous or longer for microLED applications. MicroLEDs are more tricky to compensate than OLED, where mura compensation is well known; microLED compensation needs more complex models. Within each cycle, every individual pixel is calibrated for luminance, chromaticity, dominant wavelength, size and position, and this is done in iterative loops. Speed is the enabling requirement.

The end goal is uniform brightness and color for every pixel or emitter. A further display application cited is the multiple observer application: in display, we all have different color matching functions in our eyes. That drives the need for optimized color matching functions across cross-technology product portfolios, while per-emitter luminance, chromaticity, dominant wavelength, size and position still must be measured.

In this short video, you can learn:
* Each single microLED emitter can have its own faults, cracks and defects, so it needs individual treatment rather than array-level correction.
* Metrology runs as an iterative measure-calibrate-analyze-pass/fail loop that repeats many times before an inhomogeneous display becomes homogeneous.
* Per-pixel calibration covers luminance, chromaticity, dominant wavelength, size and position, and microLED needs more complex compensation models than OLED mura.

📋 **Clip Abstract** MicroLED arrays, CPOs and optical connect devices are built from millions of emitters, each with individual faults needing individual correction, so metrology becomes an iterative measure-calibrate-analyze loop. MicroLED compensation is more complex than OLED mura, forcing speed into the loop while every pixel is calibrated for luminance, chromaticity, dominant wavelength, size and position, with color matching functions differing between observers.

About the speaker:
* Speaker: Tobias Steinel
* Company: Instrument Systems
* Event: Eindhoven 2026
* Location: High Tech Campus, Eindhoven

#MicroLEDMetrology, #PixelCalibration, #MuraCompensation, #ColorMatchingFunctions, #MicroLEDDisplays, #DisplayMetrology

More Snippets
CONTACT US

KGH Concepts GmbH

Mergenthalerallee 73-75, 65760, Eschborn

+49 17661704139

admin@techblick.com

TechBlick is owned and operated by KGH Concepts GmbH

Registration number HRB 121362

VAT number: DE 337022439

  • LinkedIn
  • YouTube

Sign up for our newsletter to receive updates on our latest speakers and events AND to receive analyst-written summaries of the key talks and happenings in our events.

Thanks for submitting!

© 2026 by KGH Concepts GmbH

bottom of page