top of page

Luigi Vesce

University of Rome Tor Vergata

* All members of the platform can watch the entire presentation.

 

Please register to become a member.

Luigi Vesce | University of Rome Tor Vergata: Can a 600 cm² carbon-electrode panel retain performance after lamination?

37:56 - 39:36

Other snippets from this talk

Summary of the clip:

Can a 600 cm² carbon-electrode panel retain performance after lamination?

The lamination stack places TPO foil between the first glass and the module and between the module and the other glass. A polyisobutylene edge sealant completes the edge. Lamination used a large lab laminator inherited from silicon PPV technology. This produced a 600 cm² panel, described as the largest-area panel with a carbon electrode.

Measured performance was 15.2, compared with 17.5 for the module without an antireflective coating. The result is presented as a good scale-up and a good demonstrator. The remaining issue cited is optimization of some connections between modules. That connection work is the explicit open item for the 600 cm² carbon-electrode panel.

The panel connects multiple modules into one laminated demonstrator. Its 15.2 performance is below the 17.5 module result measured without an antireflective coating. The talk still cites optimization of some connections between modules. The 600 cm² carbon-electrode format is therefore presented as a demonstrator, with interconnection and lamination as the practical scale-up variables to examine.

In this short video, you can learn:
* A 600 cm² carbon-electrode panel was laminated with TPO foils and a polyisobutylene edge sealant.
* The panel reached 15.2, while the module measured 17.5 without an antireflective coating.
* Some module-to-module connections still require optimization.

📋 **Clip Abstract** A 600 cm² carbon-electrode panel was laminated using TPO foil and a polyisobutylene edge sealant. The panel reached 15.2 versus 17.5 for the module without antireflective coating, with some module-to-module connections still to optimize.

About the speaker:
* Speaker: Luigi Vesce
* Company: University of Rome Tor Vergata
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#CarbonElectrodePanel, #TPOFoilLamination, #PolyisobutyleneSealant, #PerovskiteLamination, #PerovskiteSolarCells, #PrintedPhotovoltaics

This is a highlight of the presentation:

Beyond the Lab: Scaling Perovskite Solar Cells into Printed Modules

​

​

21 and 22 OCT 2026

Estrel, Berlin

Organised By:

​

​

More Highlights from the same talk.

02:42 - 04:45

Why divide a module into narrow series cells instead of scaling one large perovskite cell?

Why divide a module into narrow series cells instead of scaling one large perovskite cell?

A module is not one enlarged cell; it is an interconnection of different cells. The reason is substrate losses: a very large single cell of centimetres would suffer losses on the substrate. The module route therefore accepts division into cells connected in series, because the full large area must be segmented rather than scaled as one device.

To reduce those losses, the substrate must have low sheet resistance, around 7 to 10 ohms per square. The large area is divided into series-connected cells, and the width of those cells must be optimised to minimise loss. Interconnection area and interconnection resistance are further scale-up issues, optimisable through the laser process.

Layer inhomogeneity is another scale-up issue, linked to the printing techniques, the materials used, and the working environment. The typical IPP architecture uses P1, P2 and P3. P1 is made on the substrate to divide the cells; P2 follows deposition of all layers; P3 interrupts the counter electrode to provide one single electrode over the device.

In this short video, you can learn:
* A module interconnects multiple cells because a very large single cell would incur substrate losses.
* Low sheet resistance of about 7–10 ohms per square and optimised cell width are required to reduce losses in series-connected modules.
* P1 divides cells on the substrate, P2 follows deposition of all layers, and P3 interrupts the counter electrode.

📋 **Clip Abstract** The clip explains why perovskite scale-up uses modules made of interconnected series cells rather than one large cell: substrate losses force segmentation. It identifies low sheet resistance, optimised cell width, laser-optimised interconnection resistance and printing-related layer inhomogeneity as key scale-up issues, then introduces the P1/P2/P3 IPP architecture.

About the speaker:
* Speaker: Luigi Vesce
* Company: University of Rome Tor Vergata
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#SeriesCellInterconnection, #LowSheetResistance, #LaserInterconnection, #P1P2P3Architecture, #PerovskiteSolarCells, #PrintedElectronics

14:12 - 16:13

Why did blade coating the anti-solvent fail on large substrates, and how did slot-die restore DMSO removal?

Why did blade coating the anti-solvent fail on large substrates, and how did slot-die restore DMSO removal?

On the large-area substrate, the process stayed in ambient air but required modification: a passivation layer was added on the perovskite. The original route used the blade coater for both the perovskite and the anti-solvent. That combination produced a very poor perovskite layer, reflected in very low current, because the anti-solvent could not properly wash the DMSO from the formulation.

The failure was geometric: the meniscus at some point of the substrate could not follow the full length because the substrate is too big. So the second step was moved to a slot-die coater. This enabled effective DMSO removal across the full substrate and gave the reported 12.6% performance. They are now planning slot-die for both the first and second steps.

Even at 12.6%, the performance is not enough. The losses are caused by layer inhomogeneity. In the described flow, the blade anti-solvent limitation led to incomplete DMSO washing and poor current, while slot-die for the second step provided effective DMSO removal on the full substrate. Inhomogeneity remains the stated loss mechanism.

In this short video, you can learn:
* Blade coating both perovskite and anti-solvent on the large substrate produced a poor layer and very low current.
* The anti-solvent meniscus could not follow the full substrate length, so DMSO was not washed effectively.
* Moving the second step to slot-die removed DMSO across the full substrate and reached 12.6%, while layer inhomogeneity caused remaining losses.

📋 **Clip Abstract** Blade coating both the perovskite and anti-solvent failed on a large substrate because the meniscus could not follow the full length, leaving DMSO poorly washed and current very low. Adding a slot-die coater for the second step enabled effective DMSO removal across the full substrate and 12.6% performance, though layer inhomogeneity still caused losses.

About the speaker:
* Speaker: Luigi Vesce
* Company: University of Rome Tor Vergata
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#SlotDieCoating, #DMSOWashing, #BladeCoating, #LargeAreaPerovskite, #PerovskiteSolarCells, #PrintedElectronics

06:20 - 07:46

How does perovskite deposition follow La Mer nucleation, and why deposit 2-propanol as anti-solvent?

How does perovskite deposition follow La Mer nucleation, and why deposit 2-propanol as anti-solvent?

The deposition process is optimised around the La Mer model: a supersaturation state, burst nucleation, then perovskite crystal growth. For a triple-cation perovskite, the precursor is deposited first with air assistance to help preliminary drying. The same approach was later confirmed as good for different kinds of perovskite.

In the one-step process, an anti-solvent is then deposited. Here, 2-propanol is used to start the burst nucleation step. The final thermal step completes perovskite crystal growth. Each layer except the counter electrode and one ETL is deposited with their machine.

This process sequence places La Mer nucleation control inside the deposition machine: precursor deposition and preliminary air drying, then 2-propanol anti-solvent addition, then thermal growth. The triple-cation perovskite was the initial optimised case, and the same approach was confirmed as good for different kinds of perovskite over the years.

In this short video, you can learn:
* La Mer nucleation is mapped to supersaturation, burst nucleation and crystal growth in the perovskite deposition process.
* 2-propanol is deposited as anti-solvent to trigger burst nucleation, then the final thermal step completes crystal growth.
* The triple-cation perovskite process was optimised first and later confirmed as good for different kinds of perovskite.

📋 **Clip Abstract** The deposition of perovskite layers is optimised according to the La Mer model, with a supersaturation state, burst nucleation and crystal growth. Air-assisted precursor deposition and 2-propanol anti-solvent addition are followed by a final thermal step, and the approach was confirmed for different perovskites.

About the speaker:
* Speaker: Luigi Vesce
* Company: University of Rome Tor Vergata
* Event: Perovskite Connect 2026 | Berlin
* Location: Estrel, Berlin

Save the date: Perovskite Connect 2027 | 20 and 21 OCT 2027 | Berlin
Co-located with the Future of Electronics RESHAPED conference and exhibition
Learn more: https://www.techblick.com/perovskiteconnect

Intestered in exhibiting: learn more here: https://www.techblick.com/perovskiteconnect

#LaMerNucleation, #2PropanolAntiSolvent, #TripleCationPerovskite, #ThermalCrystalGrowth, #PerovskiteSolarCells, #PrintedElectronics

More Snippets
CONTACT US

KGH Concepts GmbH

Mergenthalerallee 73-75, 65760, Eschborn

+49 17661704139

admin@techblick.com

TechBlick is owned and operated by KGH Concepts GmbH

Registration number HRB 121362

VAT number: DE 337022439

  • LinkedIn
  • YouTube

Sign up for our newsletter to receive updates on our latest speakers and events AND to receive analyst-written summaries of the key talks and happenings in our events.

Thanks for submitting!

© 2026 by KGH Concepts GmbH

bottom of page