Summary of the clip:

Which stretchable electronics market is in production today, and which one takes over next?

Healthcare is the dominant stretchable-electronics market in production today, because wearables and stretchables go hand in hand: patients want something that conforms to the skin. A rigid piece of polyester is felt with every movement, so conformability is a functional requirement of the device rather than a cosmetic preference.

Adjacent to the medical side, sportswear brands have spent 15 to 20 years looking for a way to integrate heart rate monitors into base compression layers. That demand remains the pull for stretchable formats, keeping ink formulation pinned against both mechanical strain and the stretch-and-recover behaviour of the garment.

Robotics is the up-and-coming market. It is still a developing area precisely because it is so new for printed electronics, yet a pretty large shift into that industry is expected by the next iteration of this talk, because the applications are coming very quickly.

In this short video, you can learn:
* Medical wearables are the stretchable application already in production, driven by the patient's need for something that conforms to the skin.
* Sportswear companies have been looking for heart rate monitors integrated into base compression layers for 15 to 20 years.
* Robotics is named as the next market, with applications arriving very quickly despite being new to printed electronics.

πŸ“‹ **Clip Abstract** Production today sits in healthcare, where wearables and stretchables converge on skin-conforming devices instead of rigid polyester. Sportswear's long-sought compression-layer heart rate monitoring and a fast-moving robotics segment show where the shift goes next.

About the speaker:
* Speaker: Ryan Banfield
* Company: Heraeus Electronics
* Event: Electronics RESHAPED 2026 | Berlin
* Location: Estrel, Berlin

USA: The Future of Electronics RESHAPED | USA
πŸ“… Save the date: 9 and 10 June 2027
πŸ“ Mountain View, California (Silicon Valley)
πŸ“‹ Info: https://www.techblick.com/electronicsreshapedusa

Europe
The Future of Electronics RESHAPED | Berlin
πŸ“… Save the date: 20 and 21 October 2027
πŸ“ Berlin, Germany
πŸ“‹ Info: https://www.techblick.com/electronicsreshaped

#ConformableWearables, #CompressionLayerSensors, #MedicalWearables, #StretchableInks, #PrintedElectronics, #AdditiveElectronics

This is a highlight of the presentation:

AG Inks for Stretchable Electronics: A continuance

​

21 and 22 OCT 2026

Estrel, Berlin

Organised By:

TechBlick

​

More Highlights from the same talk.

04:00 - 05:47

Does a printed ink turning dark after a 300 Β°C ramp mean it has lost conductivity?

Does a printed ink turning dark after a 300 Β°C ramp mean it has lost conductivity?

Two discs were run in thermogravimetric analysis or DSC instrumentation. One measures weight loss, one measures energy given or taken by the material. The samples were two mainstay inks in the polymer thick film portfolio of the Heraeus Prylex group, the thick film low temperature line. They were ramped to 300 Β°C for ten minutes after a 30 Β°C burn-off of the solvents.

The two materials showed a vast color difference. The cracking on the left is due to pooling of material on the edge, not temperature; that is mud cracking seen if a print is too thick. Color is not always a huge indicator that the material does not function properly.

These are functional electronic printers, not graphic printers, so the main concerns are whether the ink is conductive, whether it works, and whether it sticks to the end of the life of the application. Storage data shown was ink taken up to 250 Β°C for 30 minutes and held.

In this short video, you can learn:
* The Heraeus Prylex polymer thick film inks were ramped to 300 Β°C for ten minutes after a 30 Β°C solvent burn-off.
* Mud cracking came from material pooling at the edge and too thick a print, not from the temperature.
* Functional electronic printing prioritizes conductivity, function, and adhesion over color, with storage data at 250 Β°C for 30 minutes.

πŸ“‹ **Clip Abstract** Two mainstay polymer thick film inks from the Heraeus Prylex group were compared after a 300 Β°C, ten-minute ramp following a 30 Β°C solvent burn-off. Color differed vastly, but the cracking was mud cracking from pooling and thick printing, and functional electronic printing cares about conductivity, function, and adhesion, with storage data at 250 Β°C for 30 minutes.

About the speaker:
* Speaker: Ryan Banfield
* Company: Heraeus Electronics
* Event: nnovation Festival: Additive, Printed, Sustainable Electronics, MicroLEDs and AR/VR Displays, Perovskites | July 2026
* Location: Online Platform

Annual access to our onsite event(s), all online events and a library featuring over 1800 presentations (recordings + PDF) across all our onsite and onsite events and technology areas. Join us and over 2000 members from around the world now.
Explore and join now --> https://www.techblick.com/

#PolymerThickFilm, #ThermogravimetricAnalysis, #SolventBurnOff, #MudCracking, #PrintedElectronics, #AdditiveElectronics

03:20 - 04:46

How much does trace geometry β€” not the ink β€” change measured stretchability, and by what factor?

How much does trace geometry β€” not the ink β€” change measured stretchability, and by what factor?

Stretchability needs definition: a customer may mean 300% once or 10% a million times. The test printed the same pattern at three widths and stretched it in two directions. That distinction frames how design choices affect one-time stretch versus repeated stretch, because β€œstretchability” alone does not specify the strain mode or cycle count.

In longitudinal testing, the serpentine trace is not printed in a straight line, so force is applied over a much smaller area as the trace stretches out. The longitudinal stress result showed an increase of about a factor of four or five times, and it was pretty even across all the traces tested.

Switching to lateral testing produced a much larger increase because the path has less of the S shape associated with the serpentine route. The takeaway is that trace geometry can change measured stretchability; design considerations matter exponentially when establishing what stretchability means for an application. The same pattern and three widths isolate that geometry effect.

In this short video, you can learn:
* The clip distinguishes 300% stretch once from 10% stretch a million times as different definitions of stretchability.
* Longitudinal serpentine testing raised stress by about four or five times, fairly evenly across three printed widths.
* Lateral testing gave a much larger increase because the trace path had less of the serpentine S shape.

πŸ“‹ **Clip Abstract** This clip shows that stretchability must be defined by strain level and cycle count, not by a single label. Using the same pattern at three widths, longitudinal serpentine traces increased stress about four or five times, while lateral testing produced a much larger increase because the path had less S shape.

About the speaker:
* Speaker: Ryan Banfield
* Company: Heraeus Electronics
* Event: Electronics RESHAPED 2026 | Berlin
* Location: Estrel, Berlin

USA: The Future of Electronics RESHAPED | USA
πŸ“… Save the date: 9 and 10 June 2027
πŸ“ Mountain View, California (Silicon Valley)
πŸ“‹ Info: https://www.techblick.com/electronicsreshapedusa

Europe
The Future of Electronics RESHAPED | Berlin
πŸ“… Save the date: 20 and 21 October 2027
πŸ“ Berlin, Germany
πŸ“‹ Info: https://www.techblick.com/electronicsreshaped

#SerpentineTraceGeometry, #LongitudinalStretchTesting, #LateralStretchTesting, #TraceWidthTestPattern, #StretchableElectronics, #PrintedElectronics

08:46 - 10:29

Are percent-shifted datasheet resistance figures correlative, and why does short-term high temperature demand polyimide over PET?

Are percent-shifted datasheet resistance figures correlative, and why does short-term high temperature demand polyimide over PET?

Technical datasheets and product presentations often contain what amounts to magic hand-waving: moving from ohm per square per mil, a normalized figure, to percent, in ways that are not correlative to your own data. The presented work instead aims to show results that correlate directly to the application being targeted, rather than a normalized number that travels badly.

Post-crease resistance change was measured to show that adhesion did not change for either material; the post-crease resistances were very similar across the high temperature exposure tested. The ASTM testing itself was not covered, and more data remains to be shared, so treat this as an indication rather than the complete dataset.

There is a common industry habit of using whatever is at hand, which invites forcing a familiar material into an application, wrenches used as hammers. Everybody uses PET because the cost is there, but high temperature stability, even short term, requires a polyimide-type substrate. Right tool, right job.

In this short video, you can learn:
* Datasheet conversions from ohm per square per mil to percent are not necessarily correlative to an application's real data.
* A crease test showed no adhesion change for either material, with post-crease resistances very similar across the high temperature exposure.
* Short-term high temperature stability still requires a polyimide substrate rather than PET, despite PET's lower cost.

πŸ“‹ **Clip Abstract** Datasheets that convert normalized ohm per square per mil values into percentages risk presenting figures that are not correlative to the target application. Crease testing showed unchanged adhesion, and the substrate message is blunt: high temperature duty, even short term, belongs on polyimide, not PET chosen for cost.

About the speaker:
* Speaker: Ryan Banfield
* Company: Heraeus Electronics
* Event: nnovation Festival: Additive, Printed, Sustainable Electronics, MicroLEDs and AR/VR Displays, Perovskites | July 2026
* Location: Online Platform

Annual access to our onsite event(s), all online events and a library featuring over 1800 presentations (recordings + PDF) across all our onsite and onsite events and technology areas. Join us and over 2000 members from around the world now.
Explore and join now --> https://www.techblick.com/

#SheetResistanceData, #CreaseTesting, #PolyimideSubstrates, #PETSubstrates, #FlexibleElectronics, #PrintedElectronics


About this talk

β†’ AG Inks for Stretchable Electronics: A continuance Β· Ryan Banfield Β· The Future of Electronics RESHAPED 2026 Berlin


Other talks by Ryan Banfield


More highlights from Ryan Banfield

More Snippets
CONTACT US

KGH Concepts GmbH

Mergenthalerallee 73-75, 65760, Eschborn

+49 17661704139

admin@techblick.com

TechBlick is owned and operated by KGH Concepts GmbH

Registration number HRB 121362

VAT number: DE 337022439

  • LinkedIn
  • YouTube

Sign up for our newsletter to receive updates on our latest speakers and events AND to receive analyst-written summaries of the key talks and happenings in our events.

Thanks for submitting!

© 2026 by KGH Concepts GmbH

bottom of page